Transient stability assessment of DFIG integrated distribution system

Kuldeep, K. Verma
{"title":"Transient stability assessment of DFIG integrated distribution system","authors":"Kuldeep, K. Verma","doi":"10.1109/CERA.2017.8343351","DOIUrl":null,"url":null,"abstract":"Integration of wind generation into the existing power grids poses significant challenges. One of the major impact is transient instability in both transmission and distribution system. In this paper, the transient stability assessment of distribution system integrated with Doubly Fed Induction Generator (DFIG) as Distributed Generation (DG) is proposed. The optimal sizing and siting of DGs with loss minimization at their different Penetration Levels (PL) is obtained by Particle Swarm Optimization (PSO) and Genetic Algorithm (GA) Techniques. The symmetrical faults at various locations are applied to the 33 bus radial distribution system to assess the transient stability of the system using time domain simulations.","PeriodicalId":286358,"journal":{"name":"2017 6th International Conference on Computer Applications In Electrical Engineering-Recent Advances (CERA)","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2017-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2017 6th International Conference on Computer Applications In Electrical Engineering-Recent Advances (CERA)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CERA.2017.8343351","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

Integration of wind generation into the existing power grids poses significant challenges. One of the major impact is transient instability in both transmission and distribution system. In this paper, the transient stability assessment of distribution system integrated with Doubly Fed Induction Generator (DFIG) as Distributed Generation (DG) is proposed. The optimal sizing and siting of DGs with loss minimization at their different Penetration Levels (PL) is obtained by Particle Swarm Optimization (PSO) and Genetic Algorithm (GA) Techniques. The symmetrical faults at various locations are applied to the 33 bus radial distribution system to assess the transient stability of the system using time domain simulations.
DFIG综合配电系统暂态稳定性评估
将风力发电整合到现有电网中提出了重大挑战。输配电系统的暂态失稳是其主要影响之一。本文提出了双馈感应发电机(DFIG)作为分布式发电(DG)的配电系统暂态稳定性评估方法。利用粒子群算法(PSO)和遗传算法(GA)求解了不同穿透水平下损失最小的dg的最优尺寸和位置。将不同位置的对称故障应用于33母线径向配电系统,采用时域仿真方法对系统暂态稳定性进行了评估。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信