The Oriented Spray Cooling System for Heat Rejection and Evaporation

C. Bowman, Robert Taylor, J. D. Hubble
{"title":"The Oriented Spray Cooling System for Heat Rejection and Evaporation","authors":"C. Bowman, Robert Taylor, J. D. Hubble","doi":"10.1115/power2019-1803","DOIUrl":null,"url":null,"abstract":"\n Spray ponds offer significant advantages over mechanical draft cooling towers (MDCT) including superior simplicity and operability, lower preferred power requirements, and lower capital and maintenance costs. Unlike a conventional spray pond in which spray nozzles are arranged in a flat bed and water is sprayed upward, the Oriented Spray Cooling System (OSCS) is an evolutionary spray pond design in which nozzles are mounted on spray trees arranged in a circle and are tilted at an angle oriented towards the center of the circle. As a result, each nozzle is exposed to essentially ambient air as water droplets drag air into the spray region while the warm air concentrated in the center of the circle rises. Both of these effects work together to increase air flow through the spray region. Increased air flow reduces the local wet-bulb temperature (LWBT) of the air in the spray pattern, promoting heat transfer and more efficient cooling. The authors have developed analytical models to predict the thermal performance of the OSCS that are based on classical heat and mass transfer and kinetic vector relationships for spherical water droplets that rely only on generic experimental thermal performance data. Therefore, the model is not limited in application with regard to spray pressure or nozzle spacing or orientation and is not limited by droplet size considerations. This paper describes specific details such as nozzle type, orientation, and drop spectrum and details on the analytical model never before published that are used to predict the OSCS performance. The paper compares the predicted performance of the OSCS with the rigorous full-scale field test results that were measured in compliance with Nuclear Regulatory Commission requirements at the Columbia Generating Station (CGS) where the ultimate heat sink (UHS) is two OSCS.","PeriodicalId":315864,"journal":{"name":"ASME 2019 Power Conference","volume":"18 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2019-07-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"ASME 2019 Power Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1115/power2019-1803","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Spray ponds offer significant advantages over mechanical draft cooling towers (MDCT) including superior simplicity and operability, lower preferred power requirements, and lower capital and maintenance costs. Unlike a conventional spray pond in which spray nozzles are arranged in a flat bed and water is sprayed upward, the Oriented Spray Cooling System (OSCS) is an evolutionary spray pond design in which nozzles are mounted on spray trees arranged in a circle and are tilted at an angle oriented towards the center of the circle. As a result, each nozzle is exposed to essentially ambient air as water droplets drag air into the spray region while the warm air concentrated in the center of the circle rises. Both of these effects work together to increase air flow through the spray region. Increased air flow reduces the local wet-bulb temperature (LWBT) of the air in the spray pattern, promoting heat transfer and more efficient cooling. The authors have developed analytical models to predict the thermal performance of the OSCS that are based on classical heat and mass transfer and kinetic vector relationships for spherical water droplets that rely only on generic experimental thermal performance data. Therefore, the model is not limited in application with regard to spray pressure or nozzle spacing or orientation and is not limited by droplet size considerations. This paper describes specific details such as nozzle type, orientation, and drop spectrum and details on the analytical model never before published that are used to predict the OSCS performance. The paper compares the predicted performance of the OSCS with the rigorous full-scale field test results that were measured in compliance with Nuclear Regulatory Commission requirements at the Columbia Generating Station (CGS) where the ultimate heat sink (UHS) is two OSCS.
定向喷淋散热蒸发冷却系统
与机械通风冷却塔(MDCT)相比,喷雾池具有显著的优势,包括优越的简单性和可操作性,更低的首选功率要求,以及更低的资本和维护成本。定向喷雾冷却系统(OSCS)是一种进化型的喷雾池设计,不同于传统的喷嘴布置在平床上,向上喷射,喷嘴安装在圆形布置的喷雾树上,并以朝向圆心的角度倾斜。因此,每个喷嘴基本上都暴露在环境空气中,因为水滴将空气拖入喷雾区域,而集中在圆圈中心的热空气上升。这两种效果共同作用,以增加通过喷雾区域的空气流量。增加的空气流量降低了喷雾模式中空气的局部湿球温度(LWBT),促进了传热和更有效的冷却。作者开发了分析模型来预测OSCS的热性能,该模型基于经典的传热传质和球形水滴的动力学矢量关系,仅依赖于一般的实验热性能数据。因此,该模型在应用中不受喷雾压力或喷嘴间距或方向的限制,也不受液滴大小的限制。本文描述了用于预测OSCS性能的具体细节,如喷嘴类型、方向和滴谱,以及以前从未发表过的分析模型的细节。本文将OSCS的预测性能与严格的全尺寸现场测试结果进行了比较,该测试结果是按照核管理委员会的要求在哥伦比亚发电站(CGS)进行的,该发电站的最终散热器(UHS)是两个OSCS。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信