Image perception of vision impaired by epi-retinal electrode stimulation

H. Cui, Shengpu Xu, Yong Hu, Li Feng, Xiaobo Xie
{"title":"Image perception of vision impaired by epi-retinal electrode stimulation","authors":"H. Cui, Shengpu Xu, Yong Hu, Li Feng, Xiaobo Xie","doi":"10.1109/IPTA.2014.7002003","DOIUrl":null,"url":null,"abstract":"This Retinal prostheses, which helps the vision impaired patients with outer retinal degeneration, uses an outside camera to detect image, convert light energy of the image into a pattern electrical stimulation signal which is transmitted to an array of electrodes placed on the retinal surface, stimulate the remaining retinal ganglion cells to elicit electric activity which is pass down to optic nerve for final processing in the brain and synthesis of a visual image. The visual pathway functions as a complex image processor as well as an information conduit. At higher levels, the visual signals arrive with significant processing completed. In reality due to its easier access, simpler processing and the retinotopic organization, the retina has been the primary focus for artificial stimulation. Studies suggest that retinal implants may provide the patients with an acceptable level of visual mobility via a typical implanted electrode array containing tens of electrodes. In this study, a wide field implantable epi-retinal microelectrode array was designed and fabricated with parylene as flexible substrate material and Pt as electrode and route material, feature test was carried out on the array, and electric characteristics of the array was tested. The feature analysis showed that morphological and electrical properties of the array well met the requirements of implantation and electrical stimulation of retina. The pattern stimulation protocols and projected visual field were discussed.","PeriodicalId":436546,"journal":{"name":"2014 4th International Conference on Image Processing Theory, Tools and Applications (IPTA)","volume":"76 6 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2014-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2014 4th International Conference on Image Processing Theory, Tools and Applications (IPTA)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IPTA.2014.7002003","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

This Retinal prostheses, which helps the vision impaired patients with outer retinal degeneration, uses an outside camera to detect image, convert light energy of the image into a pattern electrical stimulation signal which is transmitted to an array of electrodes placed on the retinal surface, stimulate the remaining retinal ganglion cells to elicit electric activity which is pass down to optic nerve for final processing in the brain and synthesis of a visual image. The visual pathway functions as a complex image processor as well as an information conduit. At higher levels, the visual signals arrive with significant processing completed. In reality due to its easier access, simpler processing and the retinotopic organization, the retina has been the primary focus for artificial stimulation. Studies suggest that retinal implants may provide the patients with an acceptable level of visual mobility via a typical implanted electrode array containing tens of electrodes. In this study, a wide field implantable epi-retinal microelectrode array was designed and fabricated with parylene as flexible substrate material and Pt as electrode and route material, feature test was carried out on the array, and electric characteristics of the array was tested. The feature analysis showed that morphological and electrical properties of the array well met the requirements of implantation and electrical stimulation of retina. The pattern stimulation protocols and projected visual field were discussed.
视网膜外电极刺激视力受损的图像感知
这种视网膜假体利用外部摄像头检测图像,将图像的光能转化为模式电刺激信号,传输到放置在视网膜表面的电极阵列,刺激剩余的视网膜神经节细胞引发电活动,该电活动传递到视神经,最终在大脑中进行处理,合成视觉图像。视觉通路既是一个复杂的图像处理器,又是一个信息通道。在更高的层次上,视觉信号到达时已经完成了重要的处理。在现实中,由于视网膜更容易获得,更简单的处理和视网膜的组织,视网膜一直是人工刺激的主要焦点。研究表明,视网膜植入物可以通过包含数十个电极的典型植入电极阵列为患者提供可接受的视觉活动水平。本研究以聚对二甲苯为柔性衬底材料,Pt为电极和路径材料,设计并制作了一种大视场植入式视网膜微电极阵列,对阵列进行了特征测试,并对阵列的电特性进行了测试。特征分析表明,该阵列的形态学和电学性能均满足视网膜植入和电刺激的要求。讨论了模式刺激方案和投影视野。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书