{"title":"Design and Development of a 36-Pulse AC-DC Converter for Vector Controlled Induction Motor Drive","authors":"B. Singh, S. Gairola","doi":"10.1109/PEDS.2007.4487778","DOIUrl":null,"url":null,"abstract":"In this paper, an autotransformer based 36-pulse AC-DC converter fed vector controlled induction motor drives (VCIMD's) is presented for reduction of harmonic-currents. A 36-pulse converter is realized using a specially designed autotransformer and two 18-pulse diode bridge rectifiers. The effect of load variation on VCIMD is also studied to demonstrate the effectiveness of the proposed AC-DC converter. A set of power quality indices on input AC mains and on DC bus for a VCIMD fed from 6-pulse and 18-pulse AC-DC converters are also given to compare their performance. It is observed that input current total harmonic distortion (THD) less than 5% is possible with the proposed topology at varying-loads. A laboratory prototype of this 36-pulse AC-DC converter is developed and test results are presented to validate the design and simulation model. It improves power quality at AC mains and meets IEEE-519 standard requirements at varying loads.","PeriodicalId":166704,"journal":{"name":"2007 7th International Conference on Power Electronics and Drive Systems","volume":"21 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2007-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"19","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2007 7th International Conference on Power Electronics and Drive Systems","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PEDS.2007.4487778","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 19
Abstract
In this paper, an autotransformer based 36-pulse AC-DC converter fed vector controlled induction motor drives (VCIMD's) is presented for reduction of harmonic-currents. A 36-pulse converter is realized using a specially designed autotransformer and two 18-pulse diode bridge rectifiers. The effect of load variation on VCIMD is also studied to demonstrate the effectiveness of the proposed AC-DC converter. A set of power quality indices on input AC mains and on DC bus for a VCIMD fed from 6-pulse and 18-pulse AC-DC converters are also given to compare their performance. It is observed that input current total harmonic distortion (THD) less than 5% is possible with the proposed topology at varying-loads. A laboratory prototype of this 36-pulse AC-DC converter is developed and test results are presented to validate the design and simulation model. It improves power quality at AC mains and meets IEEE-519 standard requirements at varying loads.