Testicular Doses of Patients Undergoing Radiological Examination of the Chest at Federal Medical Centre Makurdi, Nigeria

L. Alumuku, J. Iortile, E. Agba
{"title":"Testicular Doses of Patients Undergoing Radiological Examination of the Chest at Federal Medical Centre Makurdi, Nigeria","authors":"L. Alumuku, J. Iortile, E. Agba","doi":"10.18488/journal.72/2014.1.1/72.1.1.5","DOIUrl":null,"url":null,"abstract":"The testicular dose of eight adult male patients undergoing radiological examination of the chest were investigated at the radiological department of the Federal Medical Center (FMC) Makurdi using themoluminescent dosimetry technique. The investigation was carried out using LiF TLD discs Reader, TLD model 4500 (Harshaw Radiation measurement product USA), 3-phase diagnostic X-ray machine and single a phase X-ray machine. The Mean testicular dose of the male patients investigated was found to be 0.0662±0.0034mGy. There is also a significant correlation between testicular dose and tube potential, in which higher tube potential delivered higher values of testicular doses. Results showed that, testicular doses are within acceptable limits, which is approximately 6.6% of the 1mGy reference dose level.","PeriodicalId":236829,"journal":{"name":"International Journal of Advances in Life Science and Technology","volume":"0 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2014-06-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Advances in Life Science and Technology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.18488/journal.72/2014.1.1/72.1.1.5","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

The testicular dose of eight adult male patients undergoing radiological examination of the chest were investigated at the radiological department of the Federal Medical Center (FMC) Makurdi using themoluminescent dosimetry technique. The investigation was carried out using LiF TLD discs Reader, TLD model 4500 (Harshaw Radiation measurement product USA), 3-phase diagnostic X-ray machine and single a phase X-ray machine. The Mean testicular dose of the male patients investigated was found to be 0.0662±0.0034mGy. There is also a significant correlation between testicular dose and tube potential, in which higher tube potential delivered higher values of testicular doses. Results showed that, testicular doses are within acceptable limits, which is approximately 6.6% of the 1mGy reference dose level.
尼日利亚马库尔迪联邦医疗中心接受胸部放射检查的患者睾丸剂量
在马库尔迪联邦医疗中心(FMC)放射科使用热致发光剂量测定技术对接受胸部放射检查的8名成年男性患者的睾丸剂量进行了调查。采用LiF TLD光盘读取器、TLD型号4500(美国Harshaw辐射测量产品)、三相诊断x光机和单相x光机进行调查。男性患者睾丸平均剂量为0.0662±0.0034mGy。睾丸剂量与管电位之间也存在显著的相关性,其中管电位越高,睾丸剂量值越高。结果表明,睾丸剂量在可接受范围内,约为1mGy参考剂量水平的6.6%。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信