{"title":"Load Flow Analysis After the Entry of Renewable Power Plants in the Sulselrabar System","authors":"M. Djalal, Makmur Saini, A. Yunus","doi":"10.18196/jet.v5i2.12897","DOIUrl":null,"url":null,"abstract":"Power flow analysis in an electric power system is an analysis that reveals the performance of an electric power system and the flow of power (active and reactive) for certain conditions when the system is working. The analysis was carried out using the ETAP 16.00 software, the method used was the newton rapshon by taking a case study of normal conditions. From the results of the study, it can be seen that the power flow that occurs in each channel of the 150 kV system in the South Sulawesi system. The amount of active power (MW) that occurs during normal conditions based on the simulation is 1730.87 MW, where the active power is the largest, which is 171 MW from BUS15_TLASA to BUS13_SGMNSA. For the voltage data, there is a slight comparison of the voltage during the simulation compared to the PLN data.","PeriodicalId":402105,"journal":{"name":"Journal of Electrical Technology UMY","volume":"58 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2021-12-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Electrical Technology UMY","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.18196/jet.v5i2.12897","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

Abstract

Power flow analysis in an electric power system is an analysis that reveals the performance of an electric power system and the flow of power (active and reactive) for certain conditions when the system is working. The analysis was carried out using the ETAP 16.00 software, the method used was the newton rapshon by taking a case study of normal conditions. From the results of the study, it can be seen that the power flow that occurs in each channel of the 150 kV system in the South Sulawesi system. The amount of active power (MW) that occurs during normal conditions based on the simulation is 1730.87 MW, where the active power is the largest, which is 171 MW from BUS15_TLASA to BUS13_SGMNSA. For the voltage data, there is a slight comparison of the voltage during the simulation compared to the PLN data.
Sulselrabar系统中可再生电站入网后负荷潮流分析
电力系统潮流分析是一种揭示电力系统性能和系统工作时一定条件下的功率流(有功和无功)的分析。采用ETAP 16.00软件进行分析,以正常工况为例,采用牛顿rapshon方法。从研究结果可以看出,在南苏拉威西系统中,150 kV系统各通道中发生的潮流。仿真结果表明,在正常工况下产生的有功功率为1730.87 MW,其中BUS15_TLASA到BUS13_SGMNSA的有功功率最大,为171 MW。对于电压数据,与PLN数据相比,仿真期间的电压有轻微的比较。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信