An Approach for Passive Removal of Residual LNAPL from Groundwater

Kevin D. Svitana, J. South
{"title":"An Approach for Passive Removal of Residual LNAPL from Groundwater","authors":"Kevin D. Svitana, J. South","doi":"10.1111/gwmr.12314","DOIUrl":null,"url":null,"abstract":"Light nonaqueous phase liquids (LNAPLs) are a problematic challenge for obtaining site closure or no further action remediation sites. The source of the LNAPLs varies from leaking underground petroleum storage tanks, to manufacturing facilities where oil leaks create LNAPL accumulations beneath factory floors. Active recovery using pumping or periodic vacuum recovery from wells or sumps is used for remediation, but usually has disappointing results when LNAPL reaccumulates to thicknesses exceeding the 0.01‐foot action level recognized by many states. This paper presents a simple passive approach for recovering persistent LNAPL using nonwoven hydrophobic oil absorbing cloth. The method used laboratory trials to assess physical properties of the cloth. Parameters observed and assessed included sorptive capacity and rate, buoyancy, and LNAPL wicking. It was determined that the cloth could be rolled and secured with cable ties for placement in the wells/sumps. Two placement designs were developed, one where rolled sorbent freely floated on the well/sump fluid surface and a second where the sorbent roll was placed in the fluid column at a fixed depth. Sorbents were then used at two manufacturing facilities where LNAPLs persisted for decades. In both instances, many wells/sumps were reduced to thicknesses below the action level in less than 2 months. In most wells, LNAPL did not reaccumulate. Where it did reaccumulate, it was less than 50% of the original thickness. Using laboratory‐derived recovery rates, cloth sorbents could be sized to minimize placement/recovery frequency while effectively recovering LNAPL.","PeriodicalId":158105,"journal":{"name":"Groundwater Monitoring & Remediation","volume":"5 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2018-12-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Groundwater Monitoring & Remediation","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1111/gwmr.12314","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

Light nonaqueous phase liquids (LNAPLs) are a problematic challenge for obtaining site closure or no further action remediation sites. The source of the LNAPLs varies from leaking underground petroleum storage tanks, to manufacturing facilities where oil leaks create LNAPL accumulations beneath factory floors. Active recovery using pumping or periodic vacuum recovery from wells or sumps is used for remediation, but usually has disappointing results when LNAPL reaccumulates to thicknesses exceeding the 0.01‐foot action level recognized by many states. This paper presents a simple passive approach for recovering persistent LNAPL using nonwoven hydrophobic oil absorbing cloth. The method used laboratory trials to assess physical properties of the cloth. Parameters observed and assessed included sorptive capacity and rate, buoyancy, and LNAPL wicking. It was determined that the cloth could be rolled and secured with cable ties for placement in the wells/sumps. Two placement designs were developed, one where rolled sorbent freely floated on the well/sump fluid surface and a second where the sorbent roll was placed in the fluid column at a fixed depth. Sorbents were then used at two manufacturing facilities where LNAPLs persisted for decades. In both instances, many wells/sumps were reduced to thicknesses below the action level in less than 2 months. In most wells, LNAPL did not reaccumulate. Where it did reaccumulate, it was less than 50% of the original thickness. Using laboratory‐derived recovery rates, cloth sorbents could be sized to minimize placement/recovery frequency while effectively recovering LNAPL.
被动去除地下水中残留LNAPL的方法研究
轻质非水相液体(LNAPLs)是获得站点关闭或没有进一步行动修复站点的问题挑战。LNAPL的来源多种多样,从泄漏的地下石油储罐到石油泄漏在工厂地板下形成LNAPL积聚的制造设施。主动回收利用泵送或定期抽真空从井或污水池进行修复,但通常是令人失望的结果,当LNAPL重新积累到厚度超过0.01英尺的许多国家承认的行动水平。提出了一种利用非织造疏水吸油布回收持久性LNAPL的简单被动方法。该方法使用实验室试验来评估布料的物理特性。观察和评估的参数包括吸附能力和速率、浮力和LNAPL吸湿。经确定,可以将布卷起来,并用电缆扎带固定,以便放置在井/污水池中。开发了两种放置设计,一种是将卷起的吸附剂自由漂浮在井/池流体表面,另一种是将吸附剂卷以固定深度放置在流体柱中。吸附剂随后被用于两个制造工厂,在那里LNAPLs持续了几十年。在这两种情况下,在不到2个月的时间里,许多井/污水池的厚度都降到了作业水平以下。在大多数井中,LNAPL不会再积累。在重新积聚的地方,它的厚度小于原始厚度的50%。使用实验室衍生的回收率,布吸附剂可以调整大小,以减少放置/回收频率,同时有效地回收LNAPL。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书