{"title":"Direct Contact Applicator with Convergent Effect of EM Field for Microwave Hypertrermia","authors":"Y. Takahashi, Y. Nikawa, T. Katsumata, S. Mori, M. Nakagawa, M. Kikuchi","doi":"10.1109/MWSYM.1985.1131907","DOIUrl":null,"url":null,"abstract":"A new type applicator for microwave hyperthermia operated at 433 MHz is proposed. This applicator, which is a waveguide array type, has a convergent effect of the electromagnetic field radiated from the applicator, and focal length of can be changeable. The electric field distributions in the model of human tissues from the aperture of the applicator were measured, and the simulation of temperature distributions was performed in the model heated with the applicator.","PeriodicalId":446741,"journal":{"name":"1985 IEEE MTT-S International Microwave Symposium Digest","volume":"33 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1985-06-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"1985 IEEE MTT-S International Microwave Symposium Digest","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/MWSYM.1985.1131907","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

Abstract

A new type applicator for microwave hyperthermia operated at 433 MHz is proposed. This applicator, which is a waveguide array type, has a convergent effect of the electromagnetic field radiated from the applicator, and focal length of can be changeable. The electric field distributions in the model of human tissues from the aperture of the applicator were measured, and the simulation of temperature distributions was performed in the model heated with the applicator.
具有电磁场会聚效应的微波热疗直接接触式涂抹器
提出了一种用于433 MHz微波热疗的新型施敷器。该涂敷器为波导阵列型,对涂敷器辐射的电磁场有会聚作用,且焦距可改变。测量了施药器孔径处的电场在人体组织模型中的分布,并模拟了施药器加热模型中的温度分布。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信