Development of Self-Calibration Techniques for On-Wafer and Fixtured Measurements: A Novel Approach

L. Pradell, M. Caceres, F. Purroy
{"title":"Development of Self-Calibration Techniques for On-Wafer and Fixtured Measurements: A Novel Approach","authors":"L. Pradell, M. Caceres, F. Purroy","doi":"10.1109/EUMA.1992.335822","DOIUrl":null,"url":null,"abstract":"Network Analyzer self-calibration techniques - TRL, LMR, TAR- are developed, implemented and compared in several transmission media. A novel LMR (Line-Match-Reflect) technique based on known LINE and REFLECT Standards, is proposed and compared to conventional LMR (based on known LINE and MATCH Standards) and other techniques (TRL, TAR). They are applied to on-wafer S-parameter measurement as well as to coaxial, waveguide and microstrip media. Experimental results up to 40 GHz are presented.","PeriodicalId":317106,"journal":{"name":"1992 22nd European Microwave Conference","volume":"13 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1992-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"1992 22nd European Microwave Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/EUMA.1992.335822","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

Abstract

Network Analyzer self-calibration techniques - TRL, LMR, TAR- are developed, implemented and compared in several transmission media. A novel LMR (Line-Match-Reflect) technique based on known LINE and REFLECT Standards, is proposed and compared to conventional LMR (based on known LINE and MATCH Standards) and other techniques (TRL, TAR). They are applied to on-wafer S-parameter measurement as well as to coaxial, waveguide and microstrip media. Experimental results up to 40 GHz are presented.
片上和固定测量的自校准技术的发展:一种新方法
对网络分析仪自校准技术TRL、LMR、TAR进行了开发、实现,并在几种传输介质上进行了比较。提出了一种基于已知的LINE和REFLECT标准的新型LMR (LINE - MATCH - REFLECT)技术,并与传统的LMR(基于已知的LINE和MATCH标准)和其他技术(TRL, TAR)进行了比较。它们适用于晶圆上s参数测量以及同轴,波导和微带介质。给出了40 GHz频率下的实验结果。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信