Jianghua Yu, Zhu Liu, L. Zou, Zhihui Huang, Yongxing Wang
{"title":"Research on Voltage Sag Control Scheme Based on Fast Vacuum Switch","authors":"Jianghua Yu, Zhu Liu, L. Zou, Zhihui Huang, Yongxing Wang","doi":"10.1109/ICEPE-ST.2019.8928694","DOIUrl":null,"url":null,"abstract":"Voltage sag caused by short circuit fault will do great harm to sensitive load. In this paper, a voltage sag control scheme based on fast vacuum switch is proposed. Fast detection method is used to detect the occurrence of faults, and fast vacuum switch is used to limit the faults to a certain extent in a very short time to prevent the voltage sag from lasting too long. This paper describes the principle of the detection method, establishes the relevant mathematical model, and makes simulation analysis. At the same time, the system and fault model are established in PSCAD. The results show that the detection algorithm can detect the occurrence of faults in a very short time, control the fast switching action, and limit the duration of voltage sag to an acceptable range.","PeriodicalId":392306,"journal":{"name":"2019 5th International Conference on Electric Power Equipment - Switching Technology (ICEPE-ST)","volume":"83 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2019-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2019 5th International Conference on Electric Power Equipment - Switching Technology (ICEPE-ST)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICEPE-ST.2019.8928694","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
Voltage sag caused by short circuit fault will do great harm to sensitive load. In this paper, a voltage sag control scheme based on fast vacuum switch is proposed. Fast detection method is used to detect the occurrence of faults, and fast vacuum switch is used to limit the faults to a certain extent in a very short time to prevent the voltage sag from lasting too long. This paper describes the principle of the detection method, establishes the relevant mathematical model, and makes simulation analysis. At the same time, the system and fault model are established in PSCAD. The results show that the detection algorithm can detect the occurrence of faults in a very short time, control the fast switching action, and limit the duration of voltage sag to an acceptable range.