W. Narkbuakaew, S. Aootaphao, Chalinee Thanasupsombat, S. Thongvigitmanee
{"title":"Metal Artifact Reduction based on 2D-Projection Correction for Dental Cone-beam CT Images","authors":"W. Narkbuakaew, S. Aootaphao, Chalinee Thanasupsombat, S. Thongvigitmanee","doi":"10.1109/BMEiCON53485.2021.9745206","DOIUrl":null,"url":null,"abstract":"Metal artifacts causing dark and bright streaks normally appears in CT or CBCT data when a metallic object is embedded inside a field of view (FOV). These artifacts degrade image quality and distort anatomical structures. To solve this problem, we present a new metal artifact reduction (MAR) method. The proposed method was based on correction of 2D raw projection data and implemented as a plug-in of the reconstruction software. To accelerate computation, the proposed method used C++ and CUDA language to operate on graphic processing units (GPUs). We applied the proposed method to several dental CBCT data and executed the proposed method with full and short-scan CBCT reconstruction algorithms. The results showed that the proposed method obviously reduced the metal artifact, performed quickly, and collaborated well with both reconstruction algorithms.","PeriodicalId":380002,"journal":{"name":"2021 13th Biomedical Engineering International Conference (BMEiCON)","volume":"7 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2021-11-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2021 13th Biomedical Engineering International Conference (BMEiCON)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/BMEiCON53485.2021.9745206","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
Metal artifacts causing dark and bright streaks normally appears in CT or CBCT data when a metallic object is embedded inside a field of view (FOV). These artifacts degrade image quality and distort anatomical structures. To solve this problem, we present a new metal artifact reduction (MAR) method. The proposed method was based on correction of 2D raw projection data and implemented as a plug-in of the reconstruction software. To accelerate computation, the proposed method used C++ and CUDA language to operate on graphic processing units (GPUs). We applied the proposed method to several dental CBCT data and executed the proposed method with full and short-scan CBCT reconstruction algorithms. The results showed that the proposed method obviously reduced the metal artifact, performed quickly, and collaborated well with both reconstruction algorithms.