A Column-Row-Parallel ASIC architecture for 3D wearable / portable medical ultrasonic imaging

Kailiang Chen, Hae-Seung Lee, C. Sodini
{"title":"A Column-Row-Parallel ASIC architecture for 3D wearable / portable medical ultrasonic imaging","authors":"Kailiang Chen, Hae-Seung Lee, C. Sodini","doi":"10.1109/VLSIC.2014.6858445","DOIUrl":null,"url":null,"abstract":"A Column-Row-Parallel ASIC architecture is proposed to enable 3D wearable / portable medical ultrasound. It offers linear-scaling interconnection, acquisition and programming time, while supporting rich functionality. High voltage MUX in Tx and specially sized source follower in Rx are used to implement parallelization for improved SNR. Fault-tolerant transceiver handles defective transducer elements to increase assembly yield and allow successful system demonstration.","PeriodicalId":381216,"journal":{"name":"2014 Symposium on VLSI Circuits Digest of Technical Papers","volume":"10 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2014-06-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"21","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2014 Symposium on VLSI Circuits Digest of Technical Papers","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/VLSIC.2014.6858445","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 21

Abstract

A Column-Row-Parallel ASIC architecture is proposed to enable 3D wearable / portable medical ultrasound. It offers linear-scaling interconnection, acquisition and programming time, while supporting rich functionality. High voltage MUX in Tx and specially sized source follower in Rx are used to implement parallelization for improved SNR. Fault-tolerant transceiver handles defective transducer elements to increase assembly yield and allow successful system demonstration.
一种用于3D可穿戴/便携式医学超声成像的列-行-并行ASIC架构
提出了一种列-行-并行ASIC架构,实现了3D可穿戴/便携式医学超声。它提供线性缩放互连,采集和编程时间,同时支持丰富的功能。在Tx中使用高压MUX,在Rx中使用特殊尺寸的源从动器来实现并行化,以提高信噪比。容错收发器处理有缺陷的传感器元件,以提高装配率,并允许成功的系统演示。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信