Diagnostic Accuracy of Digital Periapical Radiography and Cone-beam Computed Tomography in Detection of Simulated External Root Resorption

A. Bakry, E. Mahmoud, M. Sayed
{"title":"Diagnostic Accuracy of Digital Periapical Radiography and Cone-beam Computed Tomography in Detection of Simulated External Root Resorption","authors":"A. Bakry, E. Mahmoud, M. Sayed","doi":"10.21608/aadj.2022.267291","DOIUrl":null,"url":null,"abstract":"Aim: The purpose of this study was to evaluate the diagnostic accuracy of digital Periapical radiography and Cone-beam Computed Tomography in Detection of Simulated External Root Resorption. Subjects and methods: This study was initiated with sample selection calculation 90 maxillary central incisors teeth. Round burs in 3 different size small, medium large were used to create simulated cavity in cervical, middle and apical root third. Digital caliper used to measure the simulated cavity. Teeth were covered by wax and mounted in block made from silicon impression putty and placed in phantom to simulated soft tissue. CBCT scan was made and digital preapical radiograph PSP was taken then the images were analysis and compared with the result gathered from digital caliper. Results: Digital preapical radiograph PSP clearly detected the simulated cavity CBCT showed statistically significantly lower mean cavity measurement than the actual measurement at cervical, middle and apical root levels (P-value <0.001), (P-value <0.001) and (P-value = 0.001), respectively in large cavity . Conclusion: Under the condition of present study, it can be conclude that there was no difference in accuracy of identifying defects between digital periapical radiographs PSP and CBCT images","PeriodicalId":136230,"journal":{"name":"Al-Azhar Assiut Dental Journal","volume":"3 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Al-Azhar Assiut Dental Journal","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.21608/aadj.2022.267291","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Aim: The purpose of this study was to evaluate the diagnostic accuracy of digital Periapical radiography and Cone-beam Computed Tomography in Detection of Simulated External Root Resorption. Subjects and methods: This study was initiated with sample selection calculation 90 maxillary central incisors teeth. Round burs in 3 different size small, medium large were used to create simulated cavity in cervical, middle and apical root third. Digital caliper used to measure the simulated cavity. Teeth were covered by wax and mounted in block made from silicon impression putty and placed in phantom to simulated soft tissue. CBCT scan was made and digital preapical radiograph PSP was taken then the images were analysis and compared with the result gathered from digital caliper. Results: Digital preapical radiograph PSP clearly detected the simulated cavity CBCT showed statistically significantly lower mean cavity measurement than the actual measurement at cervical, middle and apical root levels (P-value <0.001), (P-value <0.001) and (P-value = 0.001), respectively in large cavity . Conclusion: Under the condition of present study, it can be conclude that there was no difference in accuracy of identifying defects between digital periapical radiographs PSP and CBCT images
数字根尖周摄影和锥形束计算机断层扫描检测模拟外牙根吸收的诊断准确性
目的:本研究的目的是评估数字根尖周摄影和锥形束计算机断层扫描检测模拟外根吸收的诊断准确性。对象和方法:本研究以90颗上颌中切牙的样本选择计算开始。采用小、中、大3个不同尺寸的圆毛刺在颈、中、根尖三根处制造模拟腔体。用于测量模拟腔体的数字卡尺。牙齿被蜡覆盖,并安装在由硅压模腻子制成的块中,并放置在模拟软组织的模型中。行CBCT扫描和数字根尖前片PSP扫描,并与数字卡尺扫描结果进行对比分析。结果:数字根尖前x线片PSP清晰地探测到模拟腔体,CBCT显示大腔体在颈、中、根尖水平的平均腔体测量值分别低于实际测量值(p值<0.001)、(p值<0.001)和(p值= 0.001)。结论:在本研究条件下,数字根尖周x线片PSP与CBCT图像对缺陷的识别准确率无差异
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信