D. F. Cruz, E. Rodrigues, R. Godina, C. Cabrita, J. Matias, J. Catalão
{"title":"Novel methodology for integrated analog front-end signal processing blocks based portable multifunctional sensor for biomedical applications","authors":"D. F. Cruz, E. Rodrigues, R. Godina, C. Cabrita, J. Matias, J. Catalão","doi":"10.1109/EEEIC.2016.7555657","DOIUrl":null,"url":null,"abstract":"Photoplethysmography (PPG) sensors are an inexpensive yet cost-effective way to track data correlated to the heart pulsation. The information is acquired with light signals generated by means of a photodiode and by detecting the amount of reflected or transmitted light through the tissue. In this paper, a novel methodology that enables a systematic approach for evaluating high compact signal processing designs, which are now a trend among several semiconductor manufacturers, is proposed and discussed. In this context, an integrated pulse oximeter sensor is embedded in a custom board and used to test the methodology concept proposed by the authors. Conclusions are duly drawn.","PeriodicalId":246856,"journal":{"name":"2016 IEEE 16th International Conference on Environment and Electrical Engineering (EEEIC)","volume":"5 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2016-06-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2016 IEEE 16th International Conference on Environment and Electrical Engineering (EEEIC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/EEEIC.2016.7555657","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1
Abstract
Photoplethysmography (PPG) sensors are an inexpensive yet cost-effective way to track data correlated to the heart pulsation. The information is acquired with light signals generated by means of a photodiode and by detecting the amount of reflected or transmitted light through the tissue. In this paper, a novel methodology that enables a systematic approach for evaluating high compact signal processing designs, which are now a trend among several semiconductor manufacturers, is proposed and discussed. In this context, an integrated pulse oximeter sensor is embedded in a custom board and used to test the methodology concept proposed by the authors. Conclusions are duly drawn.