Assessment of station cable condition using wireless telemetry and diagnostic tests

H. Sedding, S. Bomben, S. Rizzetto, R. Densley
{"title":"Assessment of station cable condition using wireless telemetry and diagnostic tests","authors":"H. Sedding, S. Bomben, S. Rizzetto, R. Densley","doi":"10.1109/EEIC.2001.965676","DOIUrl":null,"url":null,"abstract":"In-service failure of 15 kV XLPE insulated cables in one of Ontario Power Generation's generating stations initiated an investigation of the root cause of breakdown. The type of failure resulted in the need to assess the condition of the remaining cables used in this application. This paper discusses the use of various analytical and diagnostic techniques used to identify the cause of failure as well as the application of wireless temperature measurements to operational condition monitoring of the remaining cables.","PeriodicalId":228071,"journal":{"name":"Proceedings: Electrical Insulation Conference and Electrical Manufacturing and Coil Winding Conference (Cat. No.01CH37264)","volume":"51 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2001-10-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"17","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings: Electrical Insulation Conference and Electrical Manufacturing and Coil Winding Conference (Cat. No.01CH37264)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/EEIC.2001.965676","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 17

Abstract

In-service failure of 15 kV XLPE insulated cables in one of Ontario Power Generation's generating stations initiated an investigation of the root cause of breakdown. The type of failure resulted in the need to assess the condition of the remaining cables used in this application. This paper discusses the use of various analytical and diagnostic techniques used to identify the cause of failure as well as the application of wireless temperature measurements to operational condition monitoring of the remaining cables.
用无线遥测和诊断试验评估站内电缆状况
安大略发电公司(Ontario Power Generation)的一个发电站的15千伏XLPE绝缘电缆在运行中发生故障,导致故障的根本原因开始调查。这种故障类型导致需要评估该应用中使用的剩余电缆的状况。本文讨论了用于确定故障原因的各种分析和诊断技术的使用,以及无线温度测量在剩余电缆运行状态监测中的应用。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信