A Low-Voltage Low-Power Implantable Telemonitoring System with Application to Endo-Hyperthermia Treatment of In-Stent Restenosis

Mengye Cai, K. Takahata, S. Mirabbasi
{"title":"A Low-Voltage Low-Power Implantable Telemonitoring System with Application to Endo-Hyperthermia Treatment of In-Stent Restenosis","authors":"Mengye Cai, K. Takahata, S. Mirabbasi","doi":"10.1109/NEWCAS49341.2020.9159803","DOIUrl":null,"url":null,"abstract":"This paper presents a low-voltage low-power implantable telemonitoring system in the context of a smart stent that uses wireless endo-hyperthermia for the treatment of in-stent restenosis. More specifically, an application specific integrated circuit (ASIC) is designed and implemented that senses the ambient temperature and wirelessly transmits the sensory information to a nearby hub. A customized “smart” stent is used as an antenna for wireless data and power transfer over the unlicensed industrial, scientific, and medical (ISM) 915 MHz and 2.4 GHz bands, respectively. For the prototype design, the ASIC is embedded on the small platform at the end of the custom-made stent that also serves as an antenna and the circuit functions without requiring any off-chip components. The proposed fully integrated solution has the following functionalities: radio-frequency (RF) telemetry, power management unit (RF -to-DC converter and voltage regulation), and temperature sensing. The proof-of-concept prototype ASIC is designed and fabricated in a $0.13-\\mu \\mathrm{m}$ CMOS process and has a chip area of 1.56 mm2. The device can detect and response to the temperature variations in the range of 30 to 50 °C. The remote power link is established when the power received by the implantable device is about −8 dBm. The data can be transmitted from the ASIC to an external hub at the power level of −28.38 dBm, with the total power consumption of 109.6 $\\mu\\mathrm{W}$.","PeriodicalId":135163,"journal":{"name":"2020 18th IEEE International New Circuits and Systems Conference (NEWCAS)","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2020-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2020 18th IEEE International New Circuits and Systems Conference (NEWCAS)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/NEWCAS49341.2020.9159803","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

This paper presents a low-voltage low-power implantable telemonitoring system in the context of a smart stent that uses wireless endo-hyperthermia for the treatment of in-stent restenosis. More specifically, an application specific integrated circuit (ASIC) is designed and implemented that senses the ambient temperature and wirelessly transmits the sensory information to a nearby hub. A customized “smart” stent is used as an antenna for wireless data and power transfer over the unlicensed industrial, scientific, and medical (ISM) 915 MHz and 2.4 GHz bands, respectively. For the prototype design, the ASIC is embedded on the small platform at the end of the custom-made stent that also serves as an antenna and the circuit functions without requiring any off-chip components. The proposed fully integrated solution has the following functionalities: radio-frequency (RF) telemetry, power management unit (RF -to-DC converter and voltage regulation), and temperature sensing. The proof-of-concept prototype ASIC is designed and fabricated in a $0.13-\mu \mathrm{m}$ CMOS process and has a chip area of 1.56 mm2. The device can detect and response to the temperature variations in the range of 30 to 50 °C. The remote power link is established when the power received by the implantable device is about −8 dBm. The data can be transmitted from the ASIC to an external hub at the power level of −28.38 dBm, with the total power consumption of 109.6 $\mu\mathrm{W}$.
低压低功率植入式远程监护系统在支架内再狭窄热疗中的应用
本文介绍了一种基于智能支架的低电压低功率植入式远程监控系统,该系统采用无线内热疗法治疗支架内再狭窄。更具体地说,设计并实现了一种专用集成电路(ASIC),可以感知环境温度,并将感知信息无线传输到附近的集线器。定制的“智能”支架被用作天线,在未经许可的工业、科学和医疗(ISM) 915mhz和2.4 GHz频段上进行无线数据和电力传输。在原型设计中,ASIC嵌入在定制支架末端的小平台上,该支架还可以用作天线和电路功能,而不需要任何片外组件。提出的完全集成的解决方案具有以下功能:射频(RF)遥测,电源管理单元(RF - dc转换器和电压调节)和温度传感。概念验证原型ASIC是在$0.13-\mu \ mathm {m}$ CMOS工艺中设计和制造的,芯片面积为1.56 mm2。该装置可以检测和响应30至50°C范围内的温度变化。当可植入设备接收到的功率约为−8dbm时,建立远程供电链路。数据可以从ASIC传输到外部集线器,功率水平为−28.38 dBm,总功耗为109.6 $\mu\ mathm {W}$。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信