Behrooz Taheri, S. A. Hosseini, Hossein Askarian‐Abyaneh, F. Razavi
{"title":"A New Method for Remote Testing Distance Relay Using Internet Protocol Version 4","authors":"Behrooz Taheri, S. A. Hosseini, Hossein Askarian‐Abyaneh, F. Razavi","doi":"10.1109/IPAPS.2019.8641918","DOIUrl":null,"url":null,"abstract":"The bulk of studies on power-system protection focus on fault detection algorithms in protective relays. However, a major part of protective relays problems come from their hidden failures. Hidden failures are not detected in the normal network state. They will be detected when an error occurs in a power grid where a relay malfunctions. This can make the power grid unstable. To prevent such an occurrence, protective relays need to be tested periodically. Such tests are very time-consuming and costly especially in remote substations. Based on the Internet Protocol Version 4 (IPv4), a new method is proposed in this paper for remote relay testing. This method allows a technician to test a relay remotely. In addition to low-level tests (such as shot test), the proposed method can carry out transient tests. The proposed method is implemented thoroughly on an AMT-105, a relay tester made by Vebko Amirkabir Company. Then the applicability of the proposed method was tested and analyzed completely using a distance relay of a real-life substation.","PeriodicalId":173653,"journal":{"name":"2019 International Conference on Protection and Automation of Power System (IPAPS)","volume":"23 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2019-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"14","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2019 International Conference on Protection and Automation of Power System (IPAPS)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IPAPS.2019.8641918","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 14
Abstract
The bulk of studies on power-system protection focus on fault detection algorithms in protective relays. However, a major part of protective relays problems come from their hidden failures. Hidden failures are not detected in the normal network state. They will be detected when an error occurs in a power grid where a relay malfunctions. This can make the power grid unstable. To prevent such an occurrence, protective relays need to be tested periodically. Such tests are very time-consuming and costly especially in remote substations. Based on the Internet Protocol Version 4 (IPv4), a new method is proposed in this paper for remote relay testing. This method allows a technician to test a relay remotely. In addition to low-level tests (such as shot test), the proposed method can carry out transient tests. The proposed method is implemented thoroughly on an AMT-105, a relay tester made by Vebko Amirkabir Company. Then the applicability of the proposed method was tested and analyzed completely using a distance relay of a real-life substation.