Procedural success in transaxillary transcatheter aortic valve implantation according to type of transcatheter heart valve: results from the multicenter TAXI registry.

A. Schäfer, O. Bhadra, L. Conradi, D. Westermann, H. Reichenspurner, O. De Backer, L. Søndergaard, W. Qureshi, N. Kakouros, I. Amat-Santos, T. Kaneko, R. Teles, T. Nolasco, M. Abecasis, N. Werner, J. Sacha, C. Trani, A. Mangieri, A. Regueiro, F. Biancari, M. Niemelä, Francesco Giannini, A. Buono, F. Bruno, M. Savontaus, A. Ielasi, P. Ferraro, G. Biondi‐Zoccai, A. Morello, A. Giordano
{"title":"Procedural success in transaxillary transcatheter aortic valve implantation according to type of transcatheter heart valve: results from the multicenter TAXI registry.","authors":"A. Schäfer, O. Bhadra, L. Conradi, D. Westermann, H. Reichenspurner, O. De Backer, L. Søndergaard, W. Qureshi, N. Kakouros, I. Amat-Santos, T. Kaneko, R. Teles, T. Nolasco, M. Abecasis, N. Werner, J. Sacha, C. Trani, A. Mangieri, A. Regueiro, F. Biancari, M. Niemelä, Francesco Giannini, A. Buono, F. Bruno, M. Savontaus, A. Ielasi, P. Ferraro, G. Biondi‐Zoccai, A. Morello, A. Giordano","doi":"10.1055/s-0043-1761794","DOIUrl":null,"url":null,"abstract":"BACKGROUND\nTransaxillary (TAx) transcatheter aortic valve implantation (TAVI) is a preferred alternative access in patients ineligible for transfemoral TAVI.\n\n\nAIMS\nThis study used the Trans-AXillary Intervention (TAXI) registry to compare procedural success according to different types of transcatheter heart valves (THV).\n\n\nMETHODS\nFor the TAXI registry anonymized data of patients treated with TAx-TAVI were collected from 18 centers. Acute procedural, early and 1-month clinical outcomes were adjudicated in accordance with standardized VARC-3 definitions.\n\n\nRESULTS\nFrom 432 patients, 368 patients (85.3%, SE group) received self-expanding (SE) THV and 64 patients (14.8%, BE group) received balloon-expandable (BE) THV. Imaging revealed lower axillary artery diameters in the SE group (max/min diameter in mm: 8.4/6.6 vs 9.4/6.8 mm; p < 0.001/p = 0.04) but a higher proportion of axillary tortuosity in BE group (62/368, 23.6% vs 26/64, 42.6%; p = 0.004) with steeper aorta-left ventricle (LV) inflow (55° vs 51°; p = 0.002) and left ventricular outflow tract (LVOT)-LV inflow angles (40.0° vs 24.5°; 0.002). TAx-TAVI was more often conducted by right sided axillary artery in the BE group (33/368, 9.0% vs 17/64, 26.6%; p < 0.001). Device success was higher in the SE group (317/368, 86.1% vs 44/64, 68.8%, p = 0.0015). In logistic regression analysis, BE THV were a risk factor for vascular complications and axillary stent implantation.\n\n\nCONCLUSIONS\nBoth, SE and BE THV can be safely used in TAx-TAVI. However, SE THV were more often used and were associated with a higher rate of device success. While SE THV were associated with lower rates of vascular complications, BE THV were more often used in cases with challenging anatomical circumstances.","PeriodicalId":401855,"journal":{"name":"Clinical research in cardiology : official journal of the German Cardiac Society","volume":"175 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2023-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Clinical research in cardiology : official journal of the German Cardiac Society","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1055/s-0043-1761794","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

BACKGROUND Transaxillary (TAx) transcatheter aortic valve implantation (TAVI) is a preferred alternative access in patients ineligible for transfemoral TAVI. AIMS This study used the Trans-AXillary Intervention (TAXI) registry to compare procedural success according to different types of transcatheter heart valves (THV). METHODS For the TAXI registry anonymized data of patients treated with TAx-TAVI were collected from 18 centers. Acute procedural, early and 1-month clinical outcomes were adjudicated in accordance with standardized VARC-3 definitions. RESULTS From 432 patients, 368 patients (85.3%, SE group) received self-expanding (SE) THV and 64 patients (14.8%, BE group) received balloon-expandable (BE) THV. Imaging revealed lower axillary artery diameters in the SE group (max/min diameter in mm: 8.4/6.6 vs 9.4/6.8 mm; p < 0.001/p = 0.04) but a higher proportion of axillary tortuosity in BE group (62/368, 23.6% vs 26/64, 42.6%; p = 0.004) with steeper aorta-left ventricle (LV) inflow (55° vs 51°; p = 0.002) and left ventricular outflow tract (LVOT)-LV inflow angles (40.0° vs 24.5°; 0.002). TAx-TAVI was more often conducted by right sided axillary artery in the BE group (33/368, 9.0% vs 17/64, 26.6%; p < 0.001). Device success was higher in the SE group (317/368, 86.1% vs 44/64, 68.8%, p = 0.0015). In logistic regression analysis, BE THV were a risk factor for vascular complications and axillary stent implantation. CONCLUSIONS Both, SE and BE THV can be safely used in TAx-TAVI. However, SE THV were more often used and were associated with a higher rate of device success. While SE THV were associated with lower rates of vascular complications, BE THV were more often used in cases with challenging anatomical circumstances.
根据经导管心脏瓣膜类型,经腋窝经导管主动脉瓣植入术的成功:来自多中心TAXI登记的结果。
背景:经腋窝(TAx)经导管主动脉瓣植入术(TAVI)是不符合经股主动脉瓣植入术条件的患者首选的替代途径。目的:本研究使用经腋窝介入(TAXI)登记来比较不同类型经导管心脏瓣膜(THV)的手术成功率。方法计程车登记收集来自18个中心的TAx-TAVI治疗患者的匿名数据。根据标准化的VARC-3定义判定急性、早期和1个月的临床结果。结果432例患者中,自扩式THV 368例(85.3%,SE组),可扩式THV 64例(14.8%,BE组)。影像学显示SE组腋窝下动脉直径(最大/分钟直径mm: 8.4/6.6 vs 9.4/6.8 mm;p < 0.001/p = 0.04),但BE组腋窝扭曲比例更高(62/368,23.6% vs 26/64, 42.6%;p = 0.004),主动脉-左心室(LV)流入更陡(55°vs 51°;p = 0.002)和左室流出道(LVOT)-左室流入角(40.0°vs 24.5°;0.002)。BE组多经右侧腋窝动脉行TAx-TAVI (33/ 368,9.0% vs 17/ 64,26.6%;p < 0.001)。SE组器械成功率更高(317/368,86.1% vs 44/64, 68.8%, p = 0.0015)。在logistic回归分析中,BE - THV是血管并发症和腋窝支架植入术的危险因素。结论SE和BE THV均可安全用于TAx-TAVI。然而,SE THV更常被使用,并且与更高的设备成功率相关。虽然SE THV与较低的血管并发症发生率相关,但BE THV更常用于具有挑战性解剖环境的病例。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信