Comparison of Thermal Conductivity Measurements of Building Insulation Materials under Various Operating Temperatures

A. Abdou, I. Budaiwi
{"title":"Comparison of Thermal Conductivity Measurements of Building Insulation Materials under Various Operating Temperatures","authors":"A. Abdou, I. Budaiwi","doi":"10.1177/1744259105056291","DOIUrl":null,"url":null,"abstract":"In harsh climates, utilizing thermal insulation in the building envelope can substantially reduce the building thermal load and consequently its energy consumption. The performance of the thermal insulation material is mainly determined by its thermal conductivity (k), which is dependent on the material’s density, porosity, moisture content, and mean temperature difference. In practice, the k-value is normally evaluated at 24 C (i.e., k24) according to relevant ASTM standards. However, when placed in the building envelope, thermal insulation materials can be exposed to significant ambient temperature and humidity variations depending on the prevailing climatic conditions. The objective of this study is to assess and compare the effect of operating temperatures on the k-value of various insulation materials commonly used in the building envelope. The k-values for seven categories of insulation materials (i.e., fiberglass, wood wool, mineral wool, rock wool, polyethylene, polyurethane, and polystyrene) are measured at different mean temperatures using an automated heat flow meter. Some preliminary measurements are reported for the purpose of assessing the impact of k-value variation on envelope-induced cooling loads (Budaiwi et al. 2002). In this study, comprehensive measurements, comparison, and analyses of results are presented and discussed. These underline the k-value degree of sensitivity ((Δk/ΔC)/k24) of various insulation materials with rising operating temperature. This would allow designers to better evaluate the thermal performance of building envelopes leading to a more realistic thermal assessment and energy requirements of buildings.","PeriodicalId":435154,"journal":{"name":"Journal of Thermal Envelope and Building Science","volume":"251 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2005-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"135","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Thermal Envelope and Building Science","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1177/1744259105056291","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 135

Abstract

In harsh climates, utilizing thermal insulation in the building envelope can substantially reduce the building thermal load and consequently its energy consumption. The performance of the thermal insulation material is mainly determined by its thermal conductivity (k), which is dependent on the material’s density, porosity, moisture content, and mean temperature difference. In practice, the k-value is normally evaluated at 24 C (i.e., k24) according to relevant ASTM standards. However, when placed in the building envelope, thermal insulation materials can be exposed to significant ambient temperature and humidity variations depending on the prevailing climatic conditions. The objective of this study is to assess and compare the effect of operating temperatures on the k-value of various insulation materials commonly used in the building envelope. The k-values for seven categories of insulation materials (i.e., fiberglass, wood wool, mineral wool, rock wool, polyethylene, polyurethane, and polystyrene) are measured at different mean temperatures using an automated heat flow meter. Some preliminary measurements are reported for the purpose of assessing the impact of k-value variation on envelope-induced cooling loads (Budaiwi et al. 2002). In this study, comprehensive measurements, comparison, and analyses of results are presented and discussed. These underline the k-value degree of sensitivity ((Δk/ΔC)/k24) of various insulation materials with rising operating temperature. This would allow designers to better evaluate the thermal performance of building envelopes leading to a more realistic thermal assessment and energy requirements of buildings.
不同工作温度下建筑保温材料导热系数测量的比较
在恶劣的气候条件下,在建筑围护结构中使用隔热材料可以大大减少建筑的热负荷,从而减少其能源消耗。保温材料的性能主要决定于它的导热系数(k),它取决于材料的密度、孔隙率、含水率和平均温差。在实际应用中,k值通常在24℃(即k24)时根据ASTM相关标准进行评估。然而,当放置在建筑围护结构中时,根据当时的气候条件,保温材料可能会暴露在显著的环境温度和湿度变化中。本研究的目的是评估和比较工作温度对建筑围护结构中常用的各种保温材料k值的影响。7类保温材料(即玻璃纤维、木棉、矿棉、岩棉、聚乙烯、聚氨酯和聚苯乙烯)的k值在不同的平均温度下使用自动热流计测量。为了评估k值变化对包络冷却负荷的影响,报道了一些初步测量结果(Budaiwi et al. 2002)。在这项研究中,综合测量,比较和分析的结果提出和讨论。这些强调了随着工作温度的升高,各种绝缘材料的k值灵敏度((Δk/ΔC)/k24)。这将使设计师能够更好地评估建筑围护结构的热性能,从而更现实地评估建筑的热性能和能源需求。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信