Dose to the shielded thymic region of irradiated mouse cadavers.

I Bojtor, I Nikl, K D Hiesche
{"title":"Dose to the shielded thymic region of irradiated mouse cadavers.","authors":"I Bojtor,&nbsp;I Nikl,&nbsp;K D Hiesche","doi":"10.3109/02841867709133956","DOIUrl":null,"url":null,"abstract":"<p><p>Frozen mouse cadavers were exposed to 220 kV roentgen irradiation with the thymic area covered with a lead plate sized 18 mm X 24 mm X 4 mm oe 18 mm X 12 mm X 4 mm. Lif-Telfon rods were used for dose measurements. With larger plate the mean dose from scattered radiation, in percent of that in the uprotected abdomen, was 12.77 (thymic lobes) and 18.34 (vertebra). With the smaller shield the figures were markedly increased, 16.70 and 23.77, respectively. Since the percentage dose is relatively high, the amount of scattered radiation may have biologic significance.</p>","PeriodicalId":7139,"journal":{"name":"Acta radiologica: therapy, physics, biology","volume":"16 4","pages":"361-8"},"PeriodicalIF":0.0000,"publicationDate":"1977-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.3109/02841867709133956","citationCount":"3","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Acta radiologica: therapy, physics, biology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3109/02841867709133956","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

Abstract

Frozen mouse cadavers were exposed to 220 kV roentgen irradiation with the thymic area covered with a lead plate sized 18 mm X 24 mm X 4 mm oe 18 mm X 12 mm X 4 mm. Lif-Telfon rods were used for dose measurements. With larger plate the mean dose from scattered radiation, in percent of that in the uprotected abdomen, was 12.77 (thymic lobes) and 18.34 (vertebra). With the smaller shield the figures were markedly increased, 16.70 and 23.77, respectively. Since the percentage dose is relatively high, the amount of scattered radiation may have biologic significance.

辐照小鼠尸体胸腺屏蔽区的剂量。
冰冻的小鼠尸体暴露在220千伏的X射线照射下,胸腺区域覆盖18毫米X 24毫米X 4毫米或18毫米X 12毫米X 4毫米的铅板。使用liff - telfon棒进行剂量测量。在较大的平板上,散射辐射的平均剂量为12.77(胸腺叶)和18.34(椎体),占未保护腹部的百分比。盾构越小,数值越显著,分别为16.70和23.77。由于百分比剂量相对较高,散射辐射量可能具有生物学意义。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信