Humidity effects in substations

T. Byrne
{"title":"Humidity effects in substations","authors":"T. Byrne","doi":"10.1109/PCICEUROPE.2014.6900056","DOIUrl":null,"url":null,"abstract":"This paper discusses the causes and effects of humidity within indoor substation environments and methods of mitigating these factors. This report briefly explains relative humidity and partial discharge, and the effect of high relative humidity on the inception or level of partial discharge. The report covers the environmental factors in switchgear design standards and the manufacturer's literature. The report covers best practice for the design of substations and internal environment control, the factors affecting the environment within a substation and methods of mitigating these factors. This report demonstrates why it is extremely important to control the substation environment and this can be achieved by minimising moisture ingress into substations and controlling the temperature and humidity within the building.","PeriodicalId":196668,"journal":{"name":"2014 Petroleum and Chemical Industry Conference Europe","volume":"20 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2014-06-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"11","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2014 Petroleum and Chemical Industry Conference Europe","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PCICEUROPE.2014.6900056","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 11

Abstract

This paper discusses the causes and effects of humidity within indoor substation environments and methods of mitigating these factors. This report briefly explains relative humidity and partial discharge, and the effect of high relative humidity on the inception or level of partial discharge. The report covers the environmental factors in switchgear design standards and the manufacturer's literature. The report covers best practice for the design of substations and internal environment control, the factors affecting the environment within a substation and methods of mitigating these factors. This report demonstrates why it is extremely important to control the substation environment and this can be achieved by minimising moisture ingress into substations and controlling the temperature and humidity within the building.
变电站的湿度影响
本文论述了变电站室内环境湿度的原因、影响及缓解这些因素的方法。本报告简要介绍了相对湿度和局部放电,以及高相对湿度对局部放电开始或水平的影响。该报告涵盖了开关柜设计标准和制造商文献中的环境因素。该报告涵盖了变电站设计和内部环境控制的最佳实践,影响变电站内环境的因素以及减轻这些因素的方法。本报告说明了为什么控制变电站环境非常重要,这可以通过最大限度地减少进入变电站的水分和控制建筑物内的温度和湿度来实现。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信