Study on the 1–3 orthotropic polymer/cement based piezoelectric composite

S. Zhai, Yongchen Wang, Bo Geng, Hong-chao Xu, Shi-feng Huang
{"title":"Study on the 1–3 orthotropic polymer/cement based piezoelectric composite","authors":"S. Zhai, Yongchen Wang, Bo Geng, Hong-chao Xu, Shi-feng Huang","doi":"10.1109/SPAWDA.2016.7829951","DOIUrl":null,"url":null,"abstract":"The 1–3 orthotropic polymer/cement based piezoelectric composite(OPCM) fabricated using PZT-51 as functional part and epoxy resin/cement as matrix via twice cutting-filling methods was to be used as acoustic emission (AE) sensors. The acoustic emission signals were collected by pencil lead-break as signal source on the concrete surface and the linear location test of signal source was carried by AE technique. The results showed that the values of signal amplitude and voltage both varied from distance and angle, it reached the maximum along the direction of 0° and 180°, which exhibited the OPCM an excellent orthotropic property. The attenuation curve showed a trend that signals of amplitude and voltage decreased sharply in near field region and reduced steadily in far field area. The OPCM used as sensors could receive each signal in the process of liner location, and the positioning accuracy could reach above 95%, which provide a basic for the OPCM to carry out health monitoring of civil engineering with AE technique.","PeriodicalId":243839,"journal":{"name":"2016 Symposium on Piezoelectricity, Acoustic Waves, and Device Applications (SPAWDA)","volume":"51 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2016-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2016 Symposium on Piezoelectricity, Acoustic Waves, and Device Applications (SPAWDA)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/SPAWDA.2016.7829951","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

The 1–3 orthotropic polymer/cement based piezoelectric composite(OPCM) fabricated using PZT-51 as functional part and epoxy resin/cement as matrix via twice cutting-filling methods was to be used as acoustic emission (AE) sensors. The acoustic emission signals were collected by pencil lead-break as signal source on the concrete surface and the linear location test of signal source was carried by AE technique. The results showed that the values of signal amplitude and voltage both varied from distance and angle, it reached the maximum along the direction of 0° and 180°, which exhibited the OPCM an excellent orthotropic property. The attenuation curve showed a trend that signals of amplitude and voltage decreased sharply in near field region and reduced steadily in far field area. The OPCM used as sensors could receive each signal in the process of liner location, and the positioning accuracy could reach above 95%, which provide a basic for the OPCM to carry out health monitoring of civil engineering with AE technique.
1-3正交异性聚合物/水泥基压电复合材料的研究
以PZT-51为功能部件,环氧树脂/水泥为基体,采用两次切割填充法制备1-3正交各向异性聚合物/水泥基压电复合材料(OPCM)作为声发射传感器。采用铅笔芯断路作为信号源采集混凝土表面的声发射信号,采用声发射技术对信号源进行线性定位测试。结果表明,信号幅值和电压随距离和角度的变化而变化,沿0°和180°方向最大,表明OPCM具有良好的正交各向异性。衰减曲线呈现幅值和电压信号在近场区急剧下降,远场区稳定下降的趋势。作为传感器的OPCM能够接收到衬垫定位过程中的各个信号,定位精度可达95%以上,为OPCM利用声发射技术进行土木工程健康监测提供了基础。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信