{"title":"Development of Thermal Stress Free SMC for Prefabricated Bathroom -Thermo Floor-","authors":"S. Yamaguchi, M. Ueno, Y. Sugioka","doi":"10.1109/ECODIM.2005.1619328","DOIUrl":null,"url":null,"abstract":"The development of the thermal stress free waterproof pan for prefabricated bathroom, thermo floor was described in this paper. For development, the evaluation methods of cold sensitive index was discussed and defined as an index of discomfort when feet touched with surface of the pan. Ceramic balloon filler was used for reducing the thermal conductivity of the material. As a physiological evaluation, the change of temperature of feet bottom and blood pressure in touching thermo floor were confirmed to be lower than in touching existing pan. So, thermo floor is effective for decreasing the thermal stress","PeriodicalId":383623,"journal":{"name":"2005 4th International Symposium on Environmentally Conscious Design and Inverse Manufacturing","volume":"867 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2005-12-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2005 4th International Symposium on Environmentally Conscious Design and Inverse Manufacturing","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ECODIM.2005.1619328","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

The development of the thermal stress free waterproof pan for prefabricated bathroom, thermo floor was described in this paper. For development, the evaluation methods of cold sensitive index was discussed and defined as an index of discomfort when feet touched with surface of the pan. Ceramic balloon filler was used for reducing the thermal conductivity of the material. As a physiological evaluation, the change of temperature of feet bottom and blood pressure in touching thermo floor were confirmed to be lower than in touching existing pan. So, thermo floor is effective for decreasing the thermal stress
预制浴室用无热应力SMC的研制——热地板
介绍了装配式浴室保温地板无热应力防水板的研制情况。为了发展,讨论了冷敏感指数的评价方法,并将其定义为脚与锅面接触时的不适感指数。采用陶瓷球囊填料来降低材料的导热性。作为一项生理评价,触摸热地板时足底温度和血压的变化比接触现有平底锅时要低。因此,热底板对于降低热应力是有效的
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信