{"title":"Arc Flash Mitigation Through Use Of Voltage Controlled/Voltage Restrained Overcurrent Elements","authors":"D. Beach, G. Johnson","doi":"10.1109/CPRE.2007.359901","DOIUrl":null,"url":null,"abstract":"This paper explores voltage controlled overcurrent and voltage controlled ground overcurrent elements which provides a means of allowing pickup currents to be set much lower than in conventional time coordinated overcurrent without loss of coordination. These systems will have circuit breaker based switchgear, overcurrent relaying at each breaker and may have other protection, although most are limited to overcurrent protection. Compared to a system using only inverse time overcurrent, use of voltage controlled overcurrent elements reduces the PPE (personal protective equipment) requirements around the switchgear in the system modeled","PeriodicalId":438320,"journal":{"name":"2007 60th Annual Conference for Protective Relay Engineers","volume":"80 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2007-03-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2007 60th Annual Conference for Protective Relay Engineers","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CPRE.2007.359901","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

Abstract

This paper explores voltage controlled overcurrent and voltage controlled ground overcurrent elements which provides a means of allowing pickup currents to be set much lower than in conventional time coordinated overcurrent without loss of coordination. These systems will have circuit breaker based switchgear, overcurrent relaying at each breaker and may have other protection, although most are limited to overcurrent protection. Compared to a system using only inverse time overcurrent, use of voltage controlled overcurrent elements reduces the PPE (personal protective equipment) requirements around the switchgear in the system modeled
通过使用电压控制/电压抑制过流元件缓解弧闪
本文探讨了电压控制过流和电压控制地过流元件,它们提供了一种方法,允许将采集电流设置得比传统的时间协调过流低得多,而不会失去协调。这些系统将有基于断路器的开关设备,在每个断路器上有过流继电器,并可能有其他保护,尽管大多数仅限于过流保护。与仅使用逆时间过流的系统相比,使用电压控制过流元件降低了系统建模中开关设备周围的PPE(个人防护设备)要求
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信