{"title":"A method to compute open area test site uncertainty using ANSI C63.4 normalized site attenuation measurement data","authors":"E.R. Heise, R. Heise","doi":"10.1109/ISEMC.1996.561422","DOIUrl":null,"url":null,"abstract":"ANSI C63.4 provides a criterion for an ideal open area test site (OATS) as normalized site attenuation (NSA) verses frequency. Using these factors, a level of uncertainty with a stated confidence level can be calculated for a given set of measurements. This level of uncertainty can be used as a measure of the quality of a test site and provides a convenient method to assess different sites.","PeriodicalId":296175,"journal":{"name":"Proceedings of Symposium on Electromagnetic Compatibility","volume":"69 10","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1996-08-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"6","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of Symposium on Electromagnetic Compatibility","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ISEMC.1996.561422","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 6
Abstract
ANSI C63.4 provides a criterion for an ideal open area test site (OATS) as normalized site attenuation (NSA) verses frequency. Using these factors, a level of uncertainty with a stated confidence level can be calculated for a given set of measurements. This level of uncertainty can be used as a measure of the quality of a test site and provides a convenient method to assess different sites.