Performance Analysis of Partial Shading Effect on PV Plant

Su Leit Naing, A. Mon
{"title":"Performance Analysis of Partial Shading Effect on PV Plant","authors":"Su Leit Naing, A. Mon","doi":"10.33093/jetap.2023.5.1.5","DOIUrl":null,"url":null,"abstract":"Partial shading of PV plants mitigate the maximum power generation of solar modules. As a result, the power output is lower than expected. It is affected not only by the number of shaded modules but also by the shaded patterns. This paper examined a PV plant rated at 15 kW connected in series-parallel for various shading patterns, such as row-wise and column-wise partial shading. This solar plant's behavior is also investigated under various irradiation levels and degrees of shading. The number of solar modules required for this plant was also evaluated. The performance results of solar modules under partial shading conditions, such as power, voltage, and current, are revealed by using the Matlab/Simulik model. From the analysis, the result shows that the column-wise shading condition generates more power output than the row-wise shading condition.","PeriodicalId":441201,"journal":{"name":"Journal of Engineering Technology and Applied Physics","volume":"15 5","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2023-03-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Engineering Technology and Applied Physics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.33093/jetap.2023.5.1.5","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Partial shading of PV plants mitigate the maximum power generation of solar modules. As a result, the power output is lower than expected. It is affected not only by the number of shaded modules but also by the shaded patterns. This paper examined a PV plant rated at 15 kW connected in series-parallel for various shading patterns, such as row-wise and column-wise partial shading. This solar plant's behavior is also investigated under various irradiation levels and degrees of shading. The number of solar modules required for this plant was also evaluated. The performance results of solar modules under partial shading conditions, such as power, voltage, and current, are revealed by using the Matlab/Simulik model. From the analysis, the result shows that the column-wise shading condition generates more power output than the row-wise shading condition.
光伏电站局部遮阳效果的性能分析
光伏电站的部分遮阳降低了太阳能组件的最大发电量。因此,输出功率低于预期。它不仅受到阴影模块数量的影响,还受到阴影模式的影响。本文研究了一个额定功率为15kw并串联的光伏电站,用于各种遮阳模式,如行式和柱式部分遮阳。在不同的照射水平和遮阳程度下,研究了该太阳能电站的性能。该工厂所需的太阳能组件数量也进行了评估。利用Matlab/Simulik模型揭示了部分遮阳条件下太阳能组件的功率、电压、电流等性能结果。分析结果表明,柱状遮阳条件比行状遮阳条件产生更大的功率输出。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信