Todd A. Brenner , Branislav Bujnak , Matthew Alverson , Alexandra T. Strauss , Anmol Singh , Saowanee Ngamruengphong , Mouen Khashab , Vikesh Singh , Eun Ji Shin , Venkata S. Akshintala
{"title":"Development and Validation of an Automated, Real-time Adenoma Detection Rate and Colonoscopy Quality Metrics Calculator","authors":"Todd A. Brenner , Branislav Bujnak , Matthew Alverson , Alexandra T. Strauss , Anmol Singh , Saowanee Ngamruengphong , Mouen Khashab , Vikesh Singh , Eun Ji Shin , Venkata S. Akshintala","doi":"10.1016/j.tige.2023.07.004","DOIUrl":null,"url":null,"abstract":"<div><h3>Background and Aims</h3><p><span>High-quality colonoscopy reduces the risk of death from colorectal cancer. The </span>adenoma detection rate (ADR) is the principal measure of colonoscopy quality but is onerous to calculate. We report the development of a fully automated platform for calculation of the ADR and other key colonoscopy quality indicators without the need for manual data entry.</p></div><div><h3>Methods</h3><p>Endoscopy<span> and pathology reports from 6 centers were collected over a 3-month period and collated using a novel data transfer interface. Text-based classification parameters were developed to identify average-risk screening colonoscopies, adenomatous pathology, cecal intubation, and withdrawal time. Automated quality metrics calculators based on these classifications were built into a web-based reporting platform, and the resulting quality metrics were benchmarked against those produced through a manual record review. Confirmation of the calculator's performance was performed in a validation cohort with data collected over a 1-month period, 6 months after the initial study.</span></p></div><div><h3>Results</h3><p>The study included 3809 colonoscopies (mean age 56.1 ± 6.40 years, 53.7% female, 38 endoscopists). The automated calculator yielded an ADR of 45.1% compared with 44.3% on manual review. Correct classification of ADR-qualifying screening colonoscopies was achieved with high predictive value, with a sensitivity of 0.918 and specificity of 1.0. The cecal intubation rate was 95.8%, and the average withdrawal time was 10:05 minutes.</p></div><div><h3>Conclusion</h3><p>We demonstrate the feasibility and performance of a colonoscopy quality reporting platform capable of calculating the ADR and other key metrics using novel, fully automated pathology report integration and a text query-based classification accessible in a wide range of practice settings.</p></div>","PeriodicalId":1,"journal":{"name":"Accounts of Chemical Research","volume":null,"pages":null},"PeriodicalIF":16.4000,"publicationDate":"2024-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Accounts of Chemical Research","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2590030723000582","RegionNum":1,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CHEMISTRY, MULTIDISCIPLINARY","Score":null,"Total":0}
引用次数: 0
Abstract
Background and Aims
High-quality colonoscopy reduces the risk of death from colorectal cancer. The adenoma detection rate (ADR) is the principal measure of colonoscopy quality but is onerous to calculate. We report the development of a fully automated platform for calculation of the ADR and other key colonoscopy quality indicators without the need for manual data entry.
Methods
Endoscopy and pathology reports from 6 centers were collected over a 3-month period and collated using a novel data transfer interface. Text-based classification parameters were developed to identify average-risk screening colonoscopies, adenomatous pathology, cecal intubation, and withdrawal time. Automated quality metrics calculators based on these classifications were built into a web-based reporting platform, and the resulting quality metrics were benchmarked against those produced through a manual record review. Confirmation of the calculator's performance was performed in a validation cohort with data collected over a 1-month period, 6 months after the initial study.
Results
The study included 3809 colonoscopies (mean age 56.1 ± 6.40 years, 53.7% female, 38 endoscopists). The automated calculator yielded an ADR of 45.1% compared with 44.3% on manual review. Correct classification of ADR-qualifying screening colonoscopies was achieved with high predictive value, with a sensitivity of 0.918 and specificity of 1.0. The cecal intubation rate was 95.8%, and the average withdrawal time was 10:05 minutes.
Conclusion
We demonstrate the feasibility and performance of a colonoscopy quality reporting platform capable of calculating the ADR and other key metrics using novel, fully automated pathology report integration and a text query-based classification accessible in a wide range of practice settings.
期刊介绍:
Accounts of Chemical Research presents short, concise and critical articles offering easy-to-read overviews of basic research and applications in all areas of chemistry and biochemistry. These short reviews focus on research from the author’s own laboratory and are designed to teach the reader about a research project. In addition, Accounts of Chemical Research publishes commentaries that give an informed opinion on a current research problem. Special Issues online are devoted to a single topic of unusual activity and significance.
Accounts of Chemical Research replaces the traditional article abstract with an article "Conspectus." These entries synopsize the research affording the reader a closer look at the content and significance of an article. Through this provision of a more detailed description of the article contents, the Conspectus enhances the article's discoverability by search engines and the exposure for the research.