An EMG readout front-end with automatic gain controller for human-computer interface

Hyeon-Cheon Seol, Young-Cheon Kwon, Seongkwan Hong, O. Kwon
{"title":"An EMG readout front-end with automatic gain controller for human-computer interface","authors":"Hyeon-Cheon Seol, Young-Cheon Kwon, Seongkwan Hong, O. Kwon","doi":"10.1109/BioCAS.2013.6679666","DOIUrl":null,"url":null,"abstract":"We propose an electromyogram (EMG) readout front-end with an automatic gain controller (AGC) for a human-computer interface (HCI). The proposed AGC adaptively controls voltage gain depending on the amplitude of the extracted EMG signal, which is varied according to the number of muscle fibers and the surface condition of the skin. Furthermore, the AGC alleviates the resolution requirement of an analog-digital converter (ADC) by fitting the maximum amplitude of the EMG signal to the full input range of the ADC. In order to obtain the wide-gain range, two variable gain amplifiers (VGAs) are used in the AGC. The voltage gain of the AGC is adjusted from 0 to 48.2 dB. A digital gain controller is employed to reduce the power consumption of the AGC. The calculated power efficiency of the AGC is 6.51 dB/μW. The proposed readout front-end is fabricated by using a 0.18 μm CMOS process technology and dissipates 19 μW at the supply voltage of 1.5 V.","PeriodicalId":344317,"journal":{"name":"2013 IEEE Biomedical Circuits and Systems Conference (BioCAS)","volume":" 12","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2013-12-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2013 IEEE Biomedical Circuits and Systems Conference (BioCAS)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/BioCAS.2013.6679666","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

We propose an electromyogram (EMG) readout front-end with an automatic gain controller (AGC) for a human-computer interface (HCI). The proposed AGC adaptively controls voltage gain depending on the amplitude of the extracted EMG signal, which is varied according to the number of muscle fibers and the surface condition of the skin. Furthermore, the AGC alleviates the resolution requirement of an analog-digital converter (ADC) by fitting the maximum amplitude of the EMG signal to the full input range of the ADC. In order to obtain the wide-gain range, two variable gain amplifiers (VGAs) are used in the AGC. The voltage gain of the AGC is adjusted from 0 to 48.2 dB. A digital gain controller is employed to reduce the power consumption of the AGC. The calculated power efficiency of the AGC is 6.51 dB/μW. The proposed readout front-end is fabricated by using a 0.18 μm CMOS process technology and dissipates 19 μW at the supply voltage of 1.5 V.
带自动增益控制器的肌电读出前端,用于人机界面
我们提出了一个肌电图(EMG)读出前端与自动增益控制器(AGC)的人机界面(HCI)。所提出的AGC根据提取的肌电信号的振幅自适应控制电压增益,肌电信号的振幅随肌纤维数量和皮肤表面状况的变化而变化。此外,AGC通过将肌电信号的最大幅度拟合到模数转换器(ADC)的整个输入范围,减轻了模数转换器(ADC)的分辨率要求。为了获得较宽的增益范围,在AGC中使用了两个可变增益放大器(VGAs)。AGC的电压增益从0到48.2 dB调节。采用数字增益控制器来降低AGC的功耗。计算出AGC的功率效率为6.51 dB/μW。该读出前端采用0.18 μm CMOS工艺,在1.5 V电源电压下功耗为19 μW。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信