Objective Assessment of Implants Stability placed in Fresh Extraction Socket using Periotest Device

G. S. Saini, M. Goyal
{"title":"Objective Assessment of Implants Stability placed in Fresh Extraction Socket using Periotest Device","authors":"G. S. Saini, M. Goyal","doi":"10.5005/JP-JOURNALS-10012-1069","DOIUrl":null,"url":null,"abstract":"Objective: To present our experience of using periotest (PT) device for measuring implant stability in immediate implants placed in fresh extraction sockets.Materials and methods: We used a PT device to measure for 10 implants placed in 10 patients over a period of 18 months. All the implants were placed immediately after extraction. The minimum follow-up period was 6 months with PT readings taken at 4th, 5th and 6th months (stage I) and after restoration at 7th, 8th and 9th months.Results: Negative values are generally considered good. This means the implant is well osseointegrated and can be loaded. The PT values for the maxillary tooth were lower than those for the mandibular tooth. A stable mandibular implant presents PT value readings between �2 and +2. A stable maxillary implant presents PT value reading between �4 and �2.Conclusion: PT enables us to assess osseointegration noninvasively and objectively in any situation. PT helps us to optimize our decision whether or not an implant is ready for functional loading.","PeriodicalId":303737,"journal":{"name":"International Journal of Oral Implantology and Clinical Research","volume":"43 3-4","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2012-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Oral Implantology and Clinical Research","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5005/JP-JOURNALS-10012-1069","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

Abstract

Objective: To present our experience of using periotest (PT) device for measuring implant stability in immediate implants placed in fresh extraction sockets.Materials and methods: We used a PT device to measure for 10 implants placed in 10 patients over a period of 18 months. All the implants were placed immediately after extraction. The minimum follow-up period was 6 months with PT readings taken at 4th, 5th and 6th months (stage I) and after restoration at 7th, 8th and 9th months.Results: Negative values are generally considered good. This means the implant is well osseointegrated and can be loaded. The PT values for the maxillary tooth were lower than those for the mandibular tooth. A stable mandibular implant presents PT value readings between �2 and +2. A stable maxillary implant presents PT value reading between �4 and �2.Conclusion: PT enables us to assess osseointegration noninvasively and objectively in any situation. PT helps us to optimize our decision whether or not an implant is ready for functional loading.
目的评价使用Periotest装置在新鲜拔牙槽内放置种植体的稳定性
目的:介绍在新鲜拔牙槽内即刻种植体中应用骨膜测试仪测量种植体稳定性的经验。材料和方法:在18个月的时间里,我们使用PT设备测量了10名患者放置的10个种植体。所有种植体在拔牙后立即放置。最短随访时间为6个月,分别在第4、5和6个月(I期)和恢复后的第7、8和9个月进行PT读数。结果:负值通常被认为是好的。这意味着种植体与骨结合良好,可以加载。上颌牙的PT值低于下颌骨的PT值。稳定的下颌种植体的PT值读数在- 2和+2之间。稳定的上颌种植体的PT值读数在4 - 2之间。结论:PT使我们能够在任何情况下无创、客观地评估骨整合。PT帮助我们优化我们的决定是否种植体已准备好进行功能负荷。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信