Transient Analysis of AC and DC Microgrid with Effective of SFCL

Mahmoud Aref, Amir Abdelmeneam, V. Oboskalov, A. Mahņitko, A. Gavrilov
{"title":"Transient Analysis of AC and DC Microgrid with Effective of SFCL","authors":"Mahmoud Aref, Amir Abdelmeneam, V. Oboskalov, A. Mahņitko, A. Gavrilov","doi":"10.1109/RTUCON.2018.8659839","DOIUrl":null,"url":null,"abstract":"Due to the increasing penetration level of microgrids (MGs), it becomes a critical issue for MGs to help sustaining power system stability. Therefore, this paper is aimed at investigating comparison between transient analysis AC and DC Microgrid connected to the grid in case of using Superconducting Fault current limiter (SFCL) at the connection point of Microgrid and grid. When the three-phase-to-ground fault is applied at connection point of Microgrid and grid, the SFCL minimized the oscillating currents and the active and reactive power of AC and DC microgrid to range 20-30%. The transient analysis of AC microgrid is better than DC microgrid except the values currents and the active and reactive power are very high during the fault. The time required to recover pre-fault values of AC microgrid (0.1 sec) is less than those time of DC microgrid (3 sec).","PeriodicalId":192943,"journal":{"name":"2018 IEEE 59th International Scientific Conference on Power and Electrical Engineering of Riga Technical University (RTUCON)","volume":"54 6","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2018-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2018 IEEE 59th International Scientific Conference on Power and Electrical Engineering of Riga Technical University (RTUCON)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/RTUCON.2018.8659839","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

Due to the increasing penetration level of microgrids (MGs), it becomes a critical issue for MGs to help sustaining power system stability. Therefore, this paper is aimed at investigating comparison between transient analysis AC and DC Microgrid connected to the grid in case of using Superconducting Fault current limiter (SFCL) at the connection point of Microgrid and grid. When the three-phase-to-ground fault is applied at connection point of Microgrid and grid, the SFCL minimized the oscillating currents and the active and reactive power of AC and DC microgrid to range 20-30%. The transient analysis of AC microgrid is better than DC microgrid except the values currents and the active and reactive power are very high during the fault. The time required to recover pre-fault values of AC microgrid (0.1 sec) is less than those time of DC microgrid (3 sec).
考虑SFCL效应的交直流微电网暂态分析
随着微电网渗透水平的不断提高,微电网如何维持电力系统的稳定已成为一个关键问题。因此,本文旨在研究在微网与电网连接点使用超导故障限流器(SFCL)的情况下,交流微网与直流微网并网的暂态分析对比。当在微网与电网连接点施加三相接地故障时,SFCL将交直流微网的振荡电流和有功功率降至20-30%。交流微网的暂态分析除故障时电流值和有功、无功功率偏高外,均优于直流微网。交流微网恢复故障前值所需时间(0.1秒)小于直流微网恢复故障前值所需时间(3秒)。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信