OPTIMIZATION OF ESTRADIOL MONITORING IN RAW AND TREATED WASTEWATER SAMPLES BY RESPONSE SURFACE METHODOLOGY

A. Queiroz, Paulo Brito, A. E. Ribeiro, Eduardo V. Carneiro, N. S. Foureaux
{"title":"OPTIMIZATION OF ESTRADIOL MONITORING IN RAW AND TREATED WASTEWATER SAMPLES BY RESPONSE SURFACE METHODOLOGY","authors":"A. Queiroz, Paulo Brito, A. E. Ribeiro, Eduardo V. Carneiro, N. S. Foureaux","doi":"10.5593/sgem2022v/3.2/s12.16","DOIUrl":null,"url":null,"abstract":"Estradiol, also designed as 17- ? -estradiol, belongs to the pharmaceutical class of steroid estrogens and was included in the �Watch List� since 2013 the Directive 2013/39/EU due to its potential risk to human health and environment. The low removal efficiency of estrogens by the conventional wastewater treatment plants, becomes a major source of their release into different aquatic matrices. This work presents the optimization of an analytical methodology based on solid phase extraction and high-performance liquid chromatography using the response surface methodology to detect and quantify 17-?- Estradiol in wastewater treatment plant effluents. From a set of 10 studied solvent/mixture compositions, pure methanol was selected as the better choice to use as mobile phase composition for liquid chromatography. The solid phase extraction step was optimized using a three-level Box-Behnken experimental design with sample volume, sample pH, adsorbent drying time and solvent composition in the washing step, as the four factors to be studied. The sample volume of 500 mL, a sample pH value adjusted to a value of 2, an adsorbent drying time of 60 min and the use of 10% of methanol in the adsorbent washing step were the obtained optimized conditions. The pH value was concluded to be the more significant parameter for average recuperations of estradiol higher than 80%. The method validation was performed by monitoring 17-?-estradiol in real wastewater treatment plant samples, collected from raw affluent, secondary treatment and treated effluent. The methodology was tested successfully, and estradiol was quantified in all the three studied samples.","PeriodicalId":331146,"journal":{"name":"SGEM International Multidisciplinary Scientific GeoConference� EXPO Proceedings","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2022-12-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"SGEM International Multidisciplinary Scientific GeoConference� EXPO Proceedings","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5593/sgem2022v/3.2/s12.16","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Estradiol, also designed as 17- ? -estradiol, belongs to the pharmaceutical class of steroid estrogens and was included in the �Watch List� since 2013 the Directive 2013/39/EU due to its potential risk to human health and environment. The low removal efficiency of estrogens by the conventional wastewater treatment plants, becomes a major source of their release into different aquatic matrices. This work presents the optimization of an analytical methodology based on solid phase extraction and high-performance liquid chromatography using the response surface methodology to detect and quantify 17-?- Estradiol in wastewater treatment plant effluents. From a set of 10 studied solvent/mixture compositions, pure methanol was selected as the better choice to use as mobile phase composition for liquid chromatography. The solid phase extraction step was optimized using a three-level Box-Behnken experimental design with sample volume, sample pH, adsorbent drying time and solvent composition in the washing step, as the four factors to be studied. The sample volume of 500 mL, a sample pH value adjusted to a value of 2, an adsorbent drying time of 60 min and the use of 10% of methanol in the adsorbent washing step were the obtained optimized conditions. The pH value was concluded to be the more significant parameter for average recuperations of estradiol higher than 80%. The method validation was performed by monitoring 17-?-estradiol in real wastewater treatment plant samples, collected from raw affluent, secondary treatment and treated effluent. The methodology was tested successfully, and estradiol was quantified in all the three studied samples.
响应面法优化原液和处理后废水中雌二醇的监测
雌二醇,也被设计成17- ?-雌二醇,属于类固醇雌激素的药物类别,由于其对人类健康和环境的潜在风险,自2013年指令2013/39/EU以来被列入“观察名单”。传统污水处理厂对雌激素的去除率较低,成为其释放到不同水生基质中的主要来源。本文提出了一种基于固相萃取和高效液相色谱的分析方法的优化,利用响应面法检测和定量17-?-污水处理厂流出物中的雌二醇。从10种溶剂/混合物组成中,选择纯甲醇作为液相色谱的流动相组成。以样品体积、样品pH、吸附剂干燥时间和洗涤步骤溶剂组成为研究因素,采用三级Box-Behnken实验设计优化固相萃取步骤。得到的最佳工艺条件为:样品体积为500 mL,样品pH值为2,吸附剂干燥时间为60 min,吸附剂洗涤步骤中甲醇用量为10%。当雌二醇的平均回收率高于80%时,pH值是最重要的参数。通过监测17-?-雌二醇在真实的污水处理厂样本,从原始富裕,二级处理和处理的流出物收集。方法测试成功,并在所有三个研究样本中进行了雌二醇的定量。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信