Evaluation of the clinical use of TLD.

B I Rudén
{"title":"Evaluation of the clinical use of TLD.","authors":"B I Rudén","doi":"10.3109/02841867609131779","DOIUrl":null,"url":null,"abstract":"<p><p>The relative light output per Gy in water for conventional roentgen radiation (20-190 kV), high energy roentgen radiation (6 and 42 MV) and electrons between 2.2 and 34.5 MeV relative to 60 Co gamma radiation is reported for different kinds of LiF dosemeters. The routine use of LiF dosemeters for a wide range of dosimetry applications in radiation therapy, the handling of the dosemeters to obtain high accuracy and the usefulness of making patient dose measurements are described.</p>","PeriodicalId":7139,"journal":{"name":"Acta radiologica: therapy, physics, biology","volume":"15 5","pages":"447-64"},"PeriodicalIF":0.0000,"publicationDate":"1976-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.3109/02841867609131779","citationCount":"36","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Acta radiologica: therapy, physics, biology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3109/02841867609131779","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 36

Abstract

The relative light output per Gy in water for conventional roentgen radiation (20-190 kV), high energy roentgen radiation (6 and 42 MV) and electrons between 2.2 and 34.5 MeV relative to 60 Co gamma radiation is reported for different kinds of LiF dosemeters. The routine use of LiF dosemeters for a wide range of dosimetry applications in radiation therapy, the handling of the dosemeters to obtain high accuracy and the usefulness of making patient dose measurements are described.

TLD的临床应用评价。
本文报道了不同种类的LiF剂量计在水中的常规x射线辐射(20-190 kV)、高能x射线辐射(6和42 MV)和电子在2.2和34.5 MeV之间(相对于60 Co伽马辐射)的相对光输出。本文介绍了LiF剂量计在放射治疗中广泛应用于剂量测定的常规用途,以及如何使用LiF剂量计以获得高准确度,以及如何进行病人剂量测量。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信