{"title":"The effect of vibration on blood flow in skeletal muscle in the rabbit.","authors":"O Huclická,&nbsp;A Wright","doi":"10.1042/cs0550471","DOIUrl":null,"url":null,"abstract":"<p><p>1. The blood flow in rabbit gastrocnemius, as measured by photoelectric drop-counter, increased when the muscle was vibrated at frequencies of 22--62 Hz. 2. Blood flow increased rapidly within 1--2 s of the start of vibration, and lasted for the whole time vibration was applied. 3. The increase in blood flow was negatively correlated with the initial blood flow, being greater with lower flows. 4. The magnitude of increase was similar in both innervated and acutely denervated muscles. 5. The arterial blood pressure did not change apart from a very brief fall at the beginning of vibration. Venous pressure rose and, consequently, the perfusion pressure was lower. The increase in blood flow thus indicates a considerable dilatation in the resistance vessels of skeletal muscle.</p>","PeriodicalId":10356,"journal":{"name":"Clinical science and molecular medicine","volume":"55 5","pages":"471-6"},"PeriodicalIF":0.0000,"publicationDate":"1978-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1042/cs0550471","citationCount":"16","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Clinical science and molecular medicine","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1042/cs0550471","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 16

Abstract

1. The blood flow in rabbit gastrocnemius, as measured by photoelectric drop-counter, increased when the muscle was vibrated at frequencies of 22--62 Hz. 2. Blood flow increased rapidly within 1--2 s of the start of vibration, and lasted for the whole time vibration was applied. 3. The increase in blood flow was negatively correlated with the initial blood flow, being greater with lower flows. 4. The magnitude of increase was similar in both innervated and acutely denervated muscles. 5. The arterial blood pressure did not change apart from a very brief fall at the beginning of vibration. Venous pressure rose and, consequently, the perfusion pressure was lower. The increase in blood flow thus indicates a considerable dilatation in the resistance vessels of skeletal muscle.

振动对家兔骨骼肌血流的影响。
1. 在22 ~ 62 Hz的振动频率下,用光电滴计数仪测量家兔腓肠肌的血流量增加。在振动开始后1 ~ 2s内血流量迅速增加,并持续整个振动时间。3.血流量的增加与初始血流量呈负相关,越低血流量越大。4. 在神经支配和急性去神经支配的肌肉中,增加的幅度相似。5. 除了振动开始时的短暂下降外,动脉血压没有变化。静脉压升高,灌注压降低。因此,血流量的增加表明骨骼肌的阻力血管有相当大的扩张。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信