Quantitative measurement of fractional bone volume using digital scanning videodensitometry.

R A Robb, J Jowsey
{"title":"Quantitative measurement of fractional bone volume using digital scanning videodensitometry.","authors":"R A Robb,&nbsp;J Jowsey","doi":"10.1007/BF02010780","DOIUrl":null,"url":null,"abstract":"<p><p>A method is described for reproducible and rapid quantitative measurements of fractional bone volume in sections of a bone biopsy. The presence or absence of bone is determined at several thousand points over the entire surface area of each specimen by high-speed digitization and computer analysis of video scans of enlarged microradiographic images of bone sections. An operator interactive light-pen assembly permits selective delineation of desired areas of the video image to facilitate computation of regional bone mass within each specimen. Tests of the reproducibility of the method of performed and are described. The results obtained from application of the method to determine the amount of bone in various age groups and in two groups of patients before and after therapy are also presented. These data indicate the potential of this technique for high volume, high resolution measurements of the fractional bone volume in both investigative and clinical diagnostic studies of age dependent and disease dependent processes.</p>","PeriodicalId":9389,"journal":{"name":"Calcified Tissue Research","volume":"25 3","pages":"265-71"},"PeriodicalIF":0.0000,"publicationDate":"1978-08-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1007/BF02010780","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Calcified Tissue Research","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1007/BF02010780","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

Abstract

A method is described for reproducible and rapid quantitative measurements of fractional bone volume in sections of a bone biopsy. The presence or absence of bone is determined at several thousand points over the entire surface area of each specimen by high-speed digitization and computer analysis of video scans of enlarged microradiographic images of bone sections. An operator interactive light-pen assembly permits selective delineation of desired areas of the video image to facilitate computation of regional bone mass within each specimen. Tests of the reproducibility of the method of performed and are described. The results obtained from application of the method to determine the amount of bone in various age groups and in two groups of patients before and after therapy are also presented. These data indicate the potential of this technique for high volume, high resolution measurements of the fractional bone volume in both investigative and clinical diagnostic studies of age dependent and disease dependent processes.

用数字扫描视频密度法定量测量骨体积分数。
描述了一种在骨活检切片中可重复和快速定量测量分数骨体积的方法。骨的存在与否是通过高速数字化和计算机分析放大的骨切片显微放射图像的视频扫描,在每个标本的整个表面积上的几千个点上确定的。操作员交互式光笔组件允许对视频图像的所需区域进行选择性描绘,以促进每个标本内区域骨量的计算。对该方法的再现性进行了测试,并进行了描述。本文还介绍了应用该方法测定不同年龄组和两组患者治疗前后骨量的结果。这些数据表明,在年龄依赖性和疾病依赖性过程的调查和临床诊断研究中,该技术具有大容量、高分辨率测量分数骨体积的潜力。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信