{"title":"A roentgen stereophotogrammetric analysis of unicompartmental knee arthroplasty.","authors":"R. Soavi, I. Loreti, L. Bragonzoni, P. La Palombara, A. Visani, M. Marcacci","doi":"10.1054/ARTH.2002.32139","DOIUrl":null,"url":null,"abstract":"Roentgen stereophotogrammetric analysis (RSA) was used to investigate the stability of the tibial component in unicompartmental knee arthroplasty. Twenty patients were implanted with a Howmedica Duracon UNI prosthesis (Limerick, Ireland) and studied for an average follow-up of 30 months. In most cases, the displacements detected at 1-year follow-up were small (ie, not exceeding 0.5 mm for translations and not exceeding 1.0 degrees for rotations). Only 1 patient showed signs of mechanical loosening as the prosthesis continued to migrate, reaching 3.2 mm of total motion at 4-year follow-up. RSA did not show any deformation in the polyethylene except for the case of loosening. The clinical results were excellent and good according to the Hospital for Special Surgery scoring system. No correlation was found among demographic, clinical, and RSA data.","PeriodicalId":280050,"journal":{"name":"The Journal of arthroplasty","volume":"31 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2002-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"17","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"The Journal of arthroplasty","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1054/ARTH.2002.32139","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 17

Abstract

Roentgen stereophotogrammetric analysis (RSA) was used to investigate the stability of the tibial component in unicompartmental knee arthroplasty. Twenty patients were implanted with a Howmedica Duracon UNI prosthesis (Limerick, Ireland) and studied for an average follow-up of 30 months. In most cases, the displacements detected at 1-year follow-up were small (ie, not exceeding 0.5 mm for translations and not exceeding 1.0 degrees for rotations). Only 1 patient showed signs of mechanical loosening as the prosthesis continued to migrate, reaching 3.2 mm of total motion at 4-year follow-up. RSA did not show any deformation in the polyethylene except for the case of loosening. The clinical results were excellent and good according to the Hospital for Special Surgery scoring system. No correlation was found among demographic, clinical, and RSA data.
单室膝关节置换术的x线立体摄影测量分析。
采用伦线立体摄影测量分析(RSA)研究单腔人工膝关节置换术中胫骨构件的稳定性。20例患者植入Howmedica Duracon UNI假体(Limerick, Ireland),平均随访30个月。在大多数情况下,1年随访时检测到的位移很小(即平移不超过0.5 mm,旋转不超过1.0度)。只有1例患者出现假体持续移位的机械松动迹象,在4年随访时达到3.2 mm的总活动。RSA在聚乙烯中没有显示出任何变形,除了松动的情况。根据特外科医院评分系统,临床效果良好。在人口统计学、临床和RSA数据之间没有发现相关性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信