Determination of Optimal PV Energy Share Considering Voltage Stability Index

Khaidir Ali, L. M. Putranto, Adha Imam, Tumiran, Muhammad Yasirroni
{"title":"Determination of Optimal PV Energy Share Considering Voltage Stability Index","authors":"Khaidir Ali, L. M. Putranto, Adha Imam, Tumiran, Muhammad Yasirroni","doi":"10.1109/SPIES48661.2020.9243039","DOIUrl":null,"url":null,"abstract":"In this study, the FPA (flower pollination algorithm) method is used for optimize the location and capacity of photovoltaic distributed considering voltage stability index (VSI). The proposed method is used in the KTN 03 bus system case study (Yogyakarta city). This operation is conducted for a half-day (10:00 AM - 2:00 PM) operation. There are two scenarios used in this study. Scenario 1 with PV placed on one bus and scenario 2 assuming all buses can be installed PV.The value generated in the two-scenario simulation, the total loss becomes 3.060 MW in scenario 1 and 3.1459 MW in scenario 2. Increased stability index values are seen on all lines. However, the smallest VSI values were obtained at lines 9, 18, and 35. The total energy loss in scenario 1 is 1.5300 MWh and scenario 2 is 1.5729 MWh. The PV energy share was obtained for 4.72% and 5.86% in both scenarios.","PeriodicalId":244426,"journal":{"name":"2020 2nd International Conference on Smart Power & Internet Energy Systems (SPIES)","volume":"44 6 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2020-09-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2020 2nd International Conference on Smart Power & Internet Energy Systems (SPIES)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/SPIES48661.2020.9243039","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

In this study, the FPA (flower pollination algorithm) method is used for optimize the location and capacity of photovoltaic distributed considering voltage stability index (VSI). The proposed method is used in the KTN 03 bus system case study (Yogyakarta city). This operation is conducted for a half-day (10:00 AM - 2:00 PM) operation. There are two scenarios used in this study. Scenario 1 with PV placed on one bus and scenario 2 assuming all buses can be installed PV.The value generated in the two-scenario simulation, the total loss becomes 3.060 MW in scenario 1 and 3.1459 MW in scenario 2. Increased stability index values are seen on all lines. However, the smallest VSI values were obtained at lines 9, 18, and 35. The total energy loss in scenario 1 is 1.5300 MWh and scenario 2 is 1.5729 MWh. The PV energy share was obtained for 4.72% and 5.86% in both scenarios.
考虑电压稳定指标的光伏发电最优能量份额确定
本研究采用FPA (flower pollination algorithm)方法,考虑电压稳定指数(VSI),对光伏分布式电站的位置和容量进行优化。所提出的方法被用于KTN 03公交系统的案例研究(日惹市)。该操作将持续半天(上午10:00 -下午2:00)。本研究中使用了两种场景。场景1将PV安装在一条总线上,场景2假设所有总线都可以安装PV。两种情景模拟产生的值,场景1的总损耗为3.060 MW,场景2的总损耗为3.1459 MW。所有管线的稳定性指数值都有所增加。然而,最小的VSI值出现在第9、18和35行。场景1的总能量损失为1.5300 MWh,场景2的总能量损失为1.5729 MWh。两种情况下,光伏发电占比分别为4.72%和5.86%。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信