Limiting hull touch voltages in large power shore connection systems during phase-to-ground faults: A solution proposal

G. Sulligoi, D. Bosich, R. Baldi, F. Tosato
{"title":"Limiting hull touch voltages in large power shore connection systems during phase-to-ground faults: A solution proposal","authors":"G. Sulligoi, D. Bosich, R. Baldi, F. Tosato","doi":"10.1109/ESTS.2013.6523757","DOIUrl":null,"url":null,"abstract":"High Voltage Shore Connection (HVSC) is a technical solution to supply ships at berth in an economic way while reducing air pollution in city ports. The increased power demand of modern cruise ships may reach several tens of MVA, requiring a primary port voltage supply at voltage >100 kV. When a phase-to-ground fault arises on the HV side, safety problems due to increasing ship hull touch voltage may arise. A possible solution is proposed in this paper, based on an HV/HV y-Δ-y transformer with secondary resistance grounded neutral in the distribution power supply utility substation, with the aim to reduce phase-to-ground fault current at port.","PeriodicalId":119318,"journal":{"name":"2013 IEEE Electric Ship Technologies Symposium (ESTS)","volume":"254 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2013-04-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"6","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2013 IEEE Electric Ship Technologies Symposium (ESTS)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ESTS.2013.6523757","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 6

Abstract

High Voltage Shore Connection (HVSC) is a technical solution to supply ships at berth in an economic way while reducing air pollution in city ports. The increased power demand of modern cruise ships may reach several tens of MVA, requiring a primary port voltage supply at voltage >100 kV. When a phase-to-ground fault arises on the HV side, safety problems due to increasing ship hull touch voltage may arise. A possible solution is proposed in this paper, based on an HV/HV y-Δ-y transformer with secondary resistance grounded neutral in the distribution power supply utility substation, with the aim to reduce phase-to-ground fault current at port.
大型电力岸接系统相地故障时船体接触电压的限制:解决方案
高压岸上连接(HVSC)是一种既能经济地为停泊船舶供电,又能减少城市港口空气污染的技术解决方案。现代游轮增加的电力需求可能达到几十MVA,需要电压>100 kV的初级港口电压供电。当高压侧发生相地故障时,可能会由于船体接触电压升高而引起安全问题。本文提出了一种可能的解决方案,以配电公用变电所中性点二次电阻接地的高压/高压y-Δ-y变压器为例,以减小端口相地故障电流。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信