E. Viennet, Boulevard de Pérolles Fribourg Arts Western Switzerland, Loïc Bouchardy
{"title":"Preliminary design and testing of a servo-hydraulic actuation system for an autonomous ankle exoskeleton","authors":"E. Viennet, Boulevard de Pérolles Fribourg Arts Western Switzerland, Loïc Bouchardy","doi":"10.25368/2020.105","DOIUrl":null,"url":null,"abstract":"The work presented in this paper aims at developing a hydraulic actuation system for an ankle exoskeleton that is able to deliver a peak power of 250 W, with a maximum torque of 90 N.m and maximum speed of 320 deg/s. After justifying the choice of a servo hydraulic actuator (SHA) over an electro hydrostatic actuator (EHA) for the targeted application, some test results of a first functional prototype are presented. The closed-loop unloaded displacement frequency response of the prototype shows a bandwidth ranging from 5 Hz to 8 Hz for displacement amplitudes between +/-5mm and +/-20mm, thus demonstrating adequate dynamic performance for normal walking speed. Then, a detailed design is proposed as a combination of commercially available components (in particular a miniature servo valve and a membrane accumulator) and a custom aluminium manifold that incorporates the hydraulic cylinder. The actuator design achieves a total weight of 1.0 kg worn at the ankle.","PeriodicalId":254837,"journal":{"name":"Volume 3 - Conference","volume":"107 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2020-06-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Volume 3 - Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.25368/2020.105","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
The work presented in this paper aims at developing a hydraulic actuation system for an ankle exoskeleton that is able to deliver a peak power of 250 W, with a maximum torque of 90 N.m and maximum speed of 320 deg/s. After justifying the choice of a servo hydraulic actuator (SHA) over an electro hydrostatic actuator (EHA) for the targeted application, some test results of a first functional prototype are presented. The closed-loop unloaded displacement frequency response of the prototype shows a bandwidth ranging from 5 Hz to 8 Hz for displacement amplitudes between +/-5mm and +/-20mm, thus demonstrating adequate dynamic performance for normal walking speed. Then, a detailed design is proposed as a combination of commercially available components (in particular a miniature servo valve and a membrane accumulator) and a custom aluminium manifold that incorporates the hydraulic cylinder. The actuator design achieves a total weight of 1.0 kg worn at the ankle.