{"title":"Physiological characteristics of trained Australian paraplegic and tetraplegic subjects.","authors":"G C Gass, E M Camp","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>Sixteen male Australian paraplegic and tetraplegic subjects competing at the 1977 FESPIC games underwent a physiological assessment. The assessment included a neurological examination, anthropometry, spirometry, maximum oxygen consumption using a wheelchair and motor driven treadmill and a 5 minute post exercise blood lactate. Eight subjects had won gold medals at international competitions for the disabled, and, at the time of testing, two of the subjects were world record holders in track and field events. Spirometry was consistent with other reported values with FVC and FEV1.0 being 4.94 and 4.25 l respectively. The cardiorespiratory data revealed a mean VO2max 2.04+/-0.64 l min-1, and 33.0+/-9.4 ml kg-1 min-1; VE STPD, 60.75+/-22.64 l min-1; maximum heart rate 179+/-20 b min-1 and post exercise lactate 11.73+/-1.94 mM. It was concluded that many physiological variables measured on the Australian subjects at rest and during maximum work were comparable to other trained disabled athletes.</p>","PeriodicalId":18528,"journal":{"name":"Medicine and science in sports","volume":"11 3","pages":"256-9"},"PeriodicalIF":0.0000,"publicationDate":"1979-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Medicine and science in sports","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
Sixteen male Australian paraplegic and tetraplegic subjects competing at the 1977 FESPIC games underwent a physiological assessment. The assessment included a neurological examination, anthropometry, spirometry, maximum oxygen consumption using a wheelchair and motor driven treadmill and a 5 minute post exercise blood lactate. Eight subjects had won gold medals at international competitions for the disabled, and, at the time of testing, two of the subjects were world record holders in track and field events. Spirometry was consistent with other reported values with FVC and FEV1.0 being 4.94 and 4.25 l respectively. The cardiorespiratory data revealed a mean VO2max 2.04+/-0.64 l min-1, and 33.0+/-9.4 ml kg-1 min-1; VE STPD, 60.75+/-22.64 l min-1; maximum heart rate 179+/-20 b min-1 and post exercise lactate 11.73+/-1.94 mM. It was concluded that many physiological variables measured on the Australian subjects at rest and during maximum work were comparable to other trained disabled athletes.
16名参加1977年FESPIC运动会的澳大利亚男性截瘫和四肢瘫痪患者接受了生理评估。评估包括神经学检查、人体测量、肺活量测定、使用轮椅和电动跑步机的最大耗氧量以及运动后5分钟血乳酸。有8个项目在国际残疾人比赛中获得金牌,在测试时,其中两个项目是田径项目的世界纪录保持者。肺活量测定与其他报道值一致,FVC和FEV1.0分别为4.94和4.25 l。心肺数据显示,平均VO2max为2.04+/-0.64 l min-1, 33.0+/-9.4 ml kg-1 min-1;VE STPD为60.75±22.64 l min-1;最大心率179+/-20 b min-1,运动后乳酸值11.73+/-1.94 mM。结论是,澳大利亚受试者在休息和最大运动期间测量的许多生理变量与其他训练过的残疾运动员相当。