{"title":"Evaluation Of The Impact Of Initial Thermal Aging On The Performances Of The Methyl Ester/Paper Composite Insulation","authors":"G. O. Boyekong, G. M. Mengounou, E. T. Nkouetcha, A. M. Imano","doi":"10.1109/ICPADM49635.2021.9493930","DOIUrl":null,"url":null,"abstract":"Oil immersed transformers are essentially used for electric power transmission. In order to improve the current safety level of distribution and power transformers, natural esters have been proposed as a reliable solution. According to various recent studies, the use of natural esters can extend the operating time of the solid insulation as compared to the use of mineral oils (MO). To reduce their viscosity, natural esters are transesterified to produce methyl esters with a kinematic viscosity below 50 centistokes. Up to date, very few literature data is available on the aging of the methyl ester/paper insulation. Hence, the aim of this work is the improvement of the understanding of the influence of thermal aging on the performances of the monoesters/paper mixed insulation. Firstly, we explain the elaboration and performance analysis processes of monoesters of palm kernel and castor oils. Then we present the aging procedure; the oil/paper composite insulation was aged during 100 hours at 110°C. Finally, we show the results of the analyses performed. Three analyses were realized, namely the determination the Total Acid Number (TAN) based on the standard ASTM D974, UV-visible spectroscopy according to the standard ASTM D6802 and finally the Breakdown Voltage (BDV) of the insulation paper based on the standard ASTM D149. For comparison, the same analyses were performed on the mineral oil/paper complex. In view of the results obtained, the excellent dielectric of monoglycerides can be confirmed.","PeriodicalId":191189,"journal":{"name":"2021 IEEE International Conference on the Properties and Applications of Dielectric Materials (ICPADM)","volume":"63 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2021-07-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2021 IEEE International Conference on the Properties and Applications of Dielectric Materials (ICPADM)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICPADM49635.2021.9493930","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Oil immersed transformers are essentially used for electric power transmission. In order to improve the current safety level of distribution and power transformers, natural esters have been proposed as a reliable solution. According to various recent studies, the use of natural esters can extend the operating time of the solid insulation as compared to the use of mineral oils (MO). To reduce their viscosity, natural esters are transesterified to produce methyl esters with a kinematic viscosity below 50 centistokes. Up to date, very few literature data is available on the aging of the methyl ester/paper insulation. Hence, the aim of this work is the improvement of the understanding of the influence of thermal aging on the performances of the monoesters/paper mixed insulation. Firstly, we explain the elaboration and performance analysis processes of monoesters of palm kernel and castor oils. Then we present the aging procedure; the oil/paper composite insulation was aged during 100 hours at 110°C. Finally, we show the results of the analyses performed. Three analyses were realized, namely the determination the Total Acid Number (TAN) based on the standard ASTM D974, UV-visible spectroscopy according to the standard ASTM D6802 and finally the Breakdown Voltage (BDV) of the insulation paper based on the standard ASTM D149. For comparison, the same analyses were performed on the mineral oil/paper complex. In view of the results obtained, the excellent dielectric of monoglycerides can be confirmed.
初始热老化对甲酯/纸复合绝缘材料性能影响的评价
油浸式变压器主要用于电力传输。为了提高配电变压器和电力变压器的安全水平,天然酯被认为是一种可靠的解决方案。根据最近的各种研究,与使用矿物油(MO)相比,使用天然酯可以延长固体绝缘的工作时间。为了降低粘度,天然酯经过酯交换反应生成运动粘度低于50厘托的甲酯。迄今为止,很少有文献数据可用于甲基酯/纸绝缘的老化。因此,这项工作的目的是提高对热老化对单酯/纸混合绝缘性能影响的认识。首先介绍了棕榈仁和蓖麻油单酯的制备及性能分析过程。然后介绍了时效过程;油/纸复合绝缘材料在110℃下老化100小时。最后,我们展示了所执行的分析结果。根据ASTM D974标准测定总酸值(TAN),根据ASTM D6802标准测定紫外可见光谱,最后根据ASTM D149标准测定绝缘纸的击穿电压(BDV)。为了进行比较,对矿物油/纸络合物进行了相同的分析。根据所得结果,可以证实单甘油酯具有优良的介电性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信