Influence of Fresh Air Change Rate on Energy Consumption of Office Buildings

Jinsong Song, Haoyu Jiang
{"title":"Influence of Fresh Air Change Rate on Energy Consumption of Office Buildings","authors":"Jinsong Song, Haoyu Jiang","doi":"10.1109/EPCE58798.2023.00032","DOIUrl":null,"url":null,"abstract":"This study provides a technical method for office building HVAC systems in hot-summer and cold-winter regions to use fresh air to bear part of the cooling load during transition seasons. The control algorithm for HVAC energy consumption based on the change of outdoor dry-bulb temperature with different ventilation times is also provided, which can reasonably utilize outdoor air to bear indoor cooling load and improve indoor air quality, significantly saving building energy consumption. For typical seasons, that is, early April to the end of May and early August to the middle of November, the energy savings vary with the change of ventilation times. This method cannot be used in summer and winter. The typical days in spring and autumn show that the more the ventilation times, the more the energy saving. Based on the experimental results, the function of the indoor HVAC power consumption changing with the ventilation times and outdoor temperature was fitted in the range of [-2, 37] °C, and this function can guide the setting of building operating conditions within the temperature range of [-2, 30] °C. According to the above changes, under the precise control for typical hot-summer and cold-winter cities, the simulation shows that this method can save 15.57% of the overall building energy consumption compared with normal HVAC operation.","PeriodicalId":355442,"journal":{"name":"2023 2nd Asia Conference on Electrical, Power and Computer Engineering (EPCE)","volume":"26 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2023-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2023 2nd Asia Conference on Electrical, Power and Computer Engineering (EPCE)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/EPCE58798.2023.00032","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

This study provides a technical method for office building HVAC systems in hot-summer and cold-winter regions to use fresh air to bear part of the cooling load during transition seasons. The control algorithm for HVAC energy consumption based on the change of outdoor dry-bulb temperature with different ventilation times is also provided, which can reasonably utilize outdoor air to bear indoor cooling load and improve indoor air quality, significantly saving building energy consumption. For typical seasons, that is, early April to the end of May and early August to the middle of November, the energy savings vary with the change of ventilation times. This method cannot be used in summer and winter. The typical days in spring and autumn show that the more the ventilation times, the more the energy saving. Based on the experimental results, the function of the indoor HVAC power consumption changing with the ventilation times and outdoor temperature was fitted in the range of [-2, 37] °C, and this function can guide the setting of building operating conditions within the temperature range of [-2, 30] °C. According to the above changes, under the precise control for typical hot-summer and cold-winter cities, the simulation shows that this method can save 15.57% of the overall building energy consumption compared with normal HVAC operation.
新风换气率对办公建筑能耗的影响
本研究为夏热冬冷地区办公楼暖通空调系统在过渡季节利用新风承担部分冷负荷提供了一种技术手段。提出了基于不同换气次数下室外干球温度变化的暖通空调能耗控制算法,可合理利用室外空气承担室内冷负荷,改善室内空气质量,显著节约建筑能耗。对于典型季节,即4月初至5月底和8月初至11月中旬,节能随换气次数的变化而变化。这种方法不能在夏季和冬季使用。春季和秋季的典型日表明,通风次数越多,节能效果越好。根据实验结果,拟合了[- 2,37]℃范围内室内暖通空调用电量随换气次数和室外温度变化的函数,该函数可指导[- 2,30]℃温度范围内建筑运行工况的设置。根据上述变化,在对典型夏热冬冷城市进行精确控制的情况下,仿真结果表明,与正常暖通空调运行相比,该方法可节约建筑总能耗15.57%。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信