Assessing oil paper insulation conditions by poles computed from Frequency Domain Spectroscopy

Y. Hadjadj, I. Fofana, F. Meghnefi, H. Ezzaidi
{"title":"Assessing oil paper insulation conditions by poles computed from Frequency Domain Spectroscopy","authors":"Y. Hadjadj, I. Fofana, F. Meghnefi, H. Ezzaidi","doi":"10.1109/ICDL.2011.6015418","DOIUrl":null,"url":null,"abstract":"In this contribution, the dielectric dissipation factor of oil impregnated paper were monitored along with the degree of polymerization. A series of experiments have been performed under controlled laboratory conditions. Since the dielectric parameters values are geometry dependent, poles which are independent of the geometry, calculated from resistances and capacitances, were considered to evaluate the condition of oil impregnated paper insulation. A correlation has been observed between the degree of polymerisation of the paper insulation and the poles values outputted from the frequency response. From the investigations performed on new and aged oil paper samples, it was shown that poles can be regarded as insulation aging indicator.","PeriodicalId":364451,"journal":{"name":"2011 IEEE International Conference on Dielectric Liquids","volume":"3 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2011-06-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"7","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2011 IEEE International Conference on Dielectric Liquids","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICDL.2011.6015418","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 7

Abstract

In this contribution, the dielectric dissipation factor of oil impregnated paper were monitored along with the degree of polymerization. A series of experiments have been performed under controlled laboratory conditions. Since the dielectric parameters values are geometry dependent, poles which are independent of the geometry, calculated from resistances and capacitances, were considered to evaluate the condition of oil impregnated paper insulation. A correlation has been observed between the degree of polymerisation of the paper insulation and the poles values outputted from the frequency response. From the investigations performed on new and aged oil paper samples, it was shown that poles can be regarded as insulation aging indicator.
用频域光谱计算的极点评价油纸绝缘条件
研究了油浸纸的介电耗散系数随聚合程度的变化规律。在受控的实验室条件下进行了一系列实验。由于介质参数值与几何形状有关,因此考虑了由电阻和电容计算的与几何形状无关的极点来评价油浸纸的绝缘状况。已观察到的相关性之间的聚合程度的纸绝缘和极值输出的频率响应。通过对新油纸和旧油纸试样的研究表明,极点可以作为绝缘老化指标。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信