{"title":"Frequency dependence of electrical conduction of composites below the percolation threshold","authors":"S. Nakamura, T. Minami, G. Sawa, K. Kitagawa","doi":"10.1109/CEIDP.1997.634593","DOIUrl":null,"url":null,"abstract":"The percolation threshold p/sub c/ of carbon black (CB)-high density polyethylene (HDPE) composites is discussed based on the critical exponent of conductivity and the change of relative permittivity with CB loading. It is concluded that p/sub c/ is the second transition where a sharp increase in conductivity for CB loading becomes gradual. There are two components in ac loss current. One is a current which is independent of frequency and becomes prevalent especially in a region just below p/sub c/. This current shows a non-ohmic behavior. The other component is due to a dielectric loss current which may take place in tunneling gaps. These results support the conclusion that the electrical conduction mechanism below p/sub c/ is tunneling.","PeriodicalId":176239,"journal":{"name":"IEEE 1997 Annual Report Conference on Electrical Insulation and Dielectric Phenomena","volume":"10 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1997-10-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE 1997 Annual Report Conference on Electrical Insulation and Dielectric Phenomena","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CEIDP.1997.634593","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

The percolation threshold p/sub c/ of carbon black (CB)-high density polyethylene (HDPE) composites is discussed based on the critical exponent of conductivity and the change of relative permittivity with CB loading. It is concluded that p/sub c/ is the second transition where a sharp increase in conductivity for CB loading becomes gradual. There are two components in ac loss current. One is a current which is independent of frequency and becomes prevalent especially in a region just below p/sub c/. This current shows a non-ohmic behavior. The other component is due to a dielectric loss current which may take place in tunneling gaps. These results support the conclusion that the electrical conduction mechanism below p/sub c/ is tunneling.
渗透阈值以下复合材料导电性的频率依赖性
根据炭黑(CB)-高密度聚乙烯(HDPE)复合材料的电导率临界指数和相对介电常数随CB载荷的变化,讨论了其渗透阈值p/sub / c/。可以得出结论,p/sub c/是第二个转变,此时CB负载的电导率急剧增加逐渐变缓。交流损耗电流有两个分量。一种是与频率无关的电流,特别是在p/sub c/以下的区域变得普遍。这个电流表现出非欧姆的特性。另一个分量是由于介电损耗电流,它可能发生在隧道间隙中。这些结果支持了p/sub / c以下的导电机制是隧穿的结论。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信