Shear Capacity of Concrete Beams with FRP Reinforcement

J. Hegger, M. Kurth
{"title":"Shear Capacity of Concrete Beams with FRP Reinforcement","authors":"J. Hegger, M. Kurth","doi":"10.14359/51682412","DOIUrl":null,"url":null,"abstract":"This paper presents an experimental and theoretical study on shear performance of concrete I-beams with fiber reinforced polymers (FRP) as internal reinforcement. A total of 24 beam tests were conducted, including tests without shear reinforcement and tests with glass fiber reinforced polymers (GFRP) stirrups and headed bars. In all specimens, GFRP bars were used as flexural reinforcement. The test variables were the ratio of shear reinforcement and the concrete strength. In the tests without stirrups, diagonal tension failure occurred. Failure due to rupture of the GFRP stirrups and headed bars was observed in the tests with lower shear reinforcement ratio of 0.75%. In the beam tests with higher ratio of 1.26% and 2.26%, respectively, depending on the concrete strength, either GFRP shear reinforcement rupture or web crushing failure occurred. Based on the results, a modified approach for calculating the shear capacity of concrete beams with FRP reinforcement was developed.","PeriodicalId":375782,"journal":{"name":"SP-275: Fiber-Reinforced Polymer Reinforcement for Concrete Structures 10th International Symposium","volume":"41 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2011-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"SP-275: Fiber-Reinforced Polymer Reinforcement for Concrete Structures 10th International Symposium","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.14359/51682412","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 4

Abstract

This paper presents an experimental and theoretical study on shear performance of concrete I-beams with fiber reinforced polymers (FRP) as internal reinforcement. A total of 24 beam tests were conducted, including tests without shear reinforcement and tests with glass fiber reinforced polymers (GFRP) stirrups and headed bars. In all specimens, GFRP bars were used as flexural reinforcement. The test variables were the ratio of shear reinforcement and the concrete strength. In the tests without stirrups, diagonal tension failure occurred. Failure due to rupture of the GFRP stirrups and headed bars was observed in the tests with lower shear reinforcement ratio of 0.75%. In the beam tests with higher ratio of 1.26% and 2.26%, respectively, depending on the concrete strength, either GFRP shear reinforcement rupture or web crushing failure occurred. Based on the results, a modified approach for calculating the shear capacity of concrete beams with FRP reinforcement was developed.
FRP加固混凝土梁抗剪承载力研究
本文对纤维增强聚合物(FRP)内配筋混凝土工字梁的抗剪性能进行了试验和理论研究。共进行了24次梁试验,包括无剪切加固试验和使用玻璃纤维增强聚合物(GFRP)箍筋和头筋的试验。所有试件均采用GFRP筋作为抗弯钢筋。试验变量为抗剪配筋比与混凝土强度。在没有马镫的试验中,发生了对角拉伸破坏。在较低的抗剪配筋率为0.75%时,试验中观察到GFRP箍筋和头筋因断裂而破坏。在比例较高的梁试验中(分别为1.26%和2.26%),根据混凝土强度的不同,GFRP抗剪钢筋发生断裂或腹板破碎破坏。在此基础上,提出了一种改进的FRP加固混凝土梁抗剪承载力计算方法。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信