Effects of Body Roundness Index on Spinal Anesthesia Block Characteristics

Nuran AKINCI EKİNCİ, M. Tutar, B. Kozanhan
{"title":"Effects of Body Roundness Index on Spinal Anesthesia Block Characteristics","authors":"Nuran AKINCI EKİNCİ, M. Tutar, B. Kozanhan","doi":"10.56728/dustad.1173736","DOIUrl":null,"url":null,"abstract":"Body roundness index (BRI) is based on the assumption that the human body's shape is an ellipse, which combines height and waist circumference. We aimed to investigate the effect of BRI on spinal anesthesia [SA] sensory levels and hypotension in patients undergoing elective surgery. In this observational study, we prospectively enrolled 18-80 years old patients with ASA physical status I-III who underwent single-shot spinal anesthesia using 15 mg 0.5% hyperbaric bupivacaine at L3–L4 intervertebral space for transurethral and lower limb surgery. Maximum sensory blockade level at 15th and 30th min, block regression time to L2 level, hypotension, bradycardia occurrence were recorded. BRI, waist, and hip circumference were found as independent predictive factors in a maximum sensory blockade level at 15th min [OR=65.7 95% CI: 1.304-3310, p=0.036; OR=0.733 95% CI: 0.558-0.963, p=0.026; OR=1.065 95% CI: 1.001-1.133, p=0.047; respectively]. Hypotension after SA was not associated with anthropometric variables. BRI can be used as a new practical tool to predict the increased cephalic spread of local anesthetic in patients undergoing SA.","PeriodicalId":299165,"journal":{"name":"DÜSTAD Dünya Sağlık ve Tabiat Bilimleri Dergisi","volume":"9 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-12-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"DÜSTAD Dünya Sağlık ve Tabiat Bilimleri Dergisi","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.56728/dustad.1173736","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Body roundness index (BRI) is based on the assumption that the human body's shape is an ellipse, which combines height and waist circumference. We aimed to investigate the effect of BRI on spinal anesthesia [SA] sensory levels and hypotension in patients undergoing elective surgery. In this observational study, we prospectively enrolled 18-80 years old patients with ASA physical status I-III who underwent single-shot spinal anesthesia using 15 mg 0.5% hyperbaric bupivacaine at L3–L4 intervertebral space for transurethral and lower limb surgery. Maximum sensory blockade level at 15th and 30th min, block regression time to L2 level, hypotension, bradycardia occurrence were recorded. BRI, waist, and hip circumference were found as independent predictive factors in a maximum sensory blockade level at 15th min [OR=65.7 95% CI: 1.304-3310, p=0.036; OR=0.733 95% CI: 0.558-0.963, p=0.026; OR=1.065 95% CI: 1.001-1.133, p=0.047; respectively]. Hypotension after SA was not associated with anthropometric variables. BRI can be used as a new practical tool to predict the increased cephalic spread of local anesthetic in patients undergoing SA.
体圆度指数对脊髓麻醉阻滞特性的影响
身体圆度指数(BRI)是基于人体形状为椭圆的假设,结合了身高和腰围。我们的目的是研究BRI对选择性手术患者脊髓麻醉感觉水平和低血压的影响。在这项观察性研究中,我们前瞻性地招募了18-80岁ASA身体状态为I-III的患者,他们在L3-L4椎间隙接受15 mg 0.5%高压布比卡因单次脊髓麻醉,进行经尿道和下肢手术。记录15 min和30 min最大感觉阻滞水平、阻滞恢复至L2水平时间、低血压、心动过缓发生情况。BRI、腰围和臀围是15分钟最大感觉封锁水平的独立预测因素[OR=65.7 95% CI: 1.304-3310, p=0.036;OR=0.733 95% CI: 0.558-0.963, p=0.026;OR=1.065 95% CI: 1.001 ~ 1.133, p=0.047;分别)。SA后的低血压与人体测量变量无关。BRI可以作为一种新的实用工具来预测局麻药在SA患者中增加的头侧扩散。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信