The development of six-channel quantitative real-time PCR filter sets for nucleic acid detection

Ruisheng Wang, S. Ren, X. Yin, Shuaifeng Zhao, Peng Gao, Jing Ma
{"title":"The development of six-channel quantitative real-time PCR filter sets for nucleic acid detection","authors":"Ruisheng Wang, S. Ren, X. Yin, Shuaifeng Zhao, Peng Gao, Jing Ma","doi":"10.1117/12.2604747","DOIUrl":null,"url":null,"abstract":"Analyzed the technical requirements of filter sets applied in 6-channel Quantitative Real-time PCR nucleic acid detection, and these filters meet the requirements were designed with double sides coating on single glass substrate, while each coating was about 200 layers. These coatings were manufactured on a plasma-assisted reactive magnetic sputtering (PARMS) machine, and the thickness error is less than 0.1%. Finally, the transmittance rates of these 6-channel real-time fluorescence PCR filters are <93%, the cut-off steepness was less than 1%, and the crosstalk was less than 1% in polychromatic fluorescence PCR.","PeriodicalId":236529,"journal":{"name":"International Symposium on Advanced Optical Manufacturing and Testing Technologies (AOMATT)","volume":"20 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2021-12-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Symposium on Advanced Optical Manufacturing and Testing Technologies (AOMATT)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1117/12.2604747","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

Analyzed the technical requirements of filter sets applied in 6-channel Quantitative Real-time PCR nucleic acid detection, and these filters meet the requirements were designed with double sides coating on single glass substrate, while each coating was about 200 layers. These coatings were manufactured on a plasma-assisted reactive magnetic sputtering (PARMS) machine, and the thickness error is less than 0.1%. Finally, the transmittance rates of these 6-channel real-time fluorescence PCR filters are <93%, the cut-off steepness was less than 1%, and the crosstalk was less than 1% in polychromatic fluorescence PCR.
核酸检测用六通道实时定量PCR过滤装置的研制
分析了用于6通道定量实时PCR核酸检测的滤光片的技术要求,满足要求的滤光片设计为单层玻璃基板双面涂布,每次涂布约200层。这些涂层是在等离子体辅助反应磁溅射(PARMS)机上制备的,厚度误差小于0.1%。最后,6通道实时荧光PCR滤镜的透光率<93%,截止陡峭度小于1%,多色荧光PCR串扰小于1%。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信