{"title":"Distributed Second Order Sliding Modes for Optimal Load Frequency Control","authors":"M. Cucuzzella, Sebastian Trip, C. D. Persis, A. Ferrara","doi":"10.23919/ACC.2017.7963480","DOIUrl":null,"url":null,"abstract":"This paper proposes a Distributed Second Order Sliding Mode (D-SOSM) control strategy for Optimal Load Frequency Control (OLFC) in power networks, where besides frequency regulation also minimization of generation costs is achieved. Because of unknown load dynamics and possible network parameters uncertainties, the sliding mode control methodology is particularly appropriate for the considered control problem. This paper considers a power network partitioned into control areas, where each area is modelled by an equivalent generator including second-order turbine-governor dynamics. On a suitable designed sliding manifold, the controlled system exhibits an incremental passivity property that allows us to infer convergence to a zero steady state frequency deviation minimizing the generation costs.","PeriodicalId":422926,"journal":{"name":"2017 American Control Conference (ACC)","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2017-07-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"17","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2017 American Control Conference (ACC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.23919/ACC.2017.7963480","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 17

Abstract

This paper proposes a Distributed Second Order Sliding Mode (D-SOSM) control strategy for Optimal Load Frequency Control (OLFC) in power networks, where besides frequency regulation also minimization of generation costs is achieved. Because of unknown load dynamics and possible network parameters uncertainties, the sliding mode control methodology is particularly appropriate for the considered control problem. This paper considers a power network partitioned into control areas, where each area is modelled by an equivalent generator including second-order turbine-governor dynamics. On a suitable designed sliding manifold, the controlled system exhibits an incremental passivity property that allows us to infer convergence to a zero steady state frequency deviation minimizing the generation costs.
最优负荷频率控制的分布二阶滑模
本文提出了一种分布式二阶滑模(D-SOSM)控制策略,用于电网最优负荷频率控制(OLFC),除频率调节外,还能实现发电成本的最小化。由于未知的负载动态和可能的网络参数不确定性,滑模控制方法特别适用于所考虑的控制问题。本文考虑将电网划分为多个控制区域,每个控制区域由一个包含二阶涡轮调速器动力学的等效发电机建模。在设计合适的滑动歧管上,被控系统显示出增量无源特性,使我们能够推断收敛到零稳态频率偏差,从而使发电成本最小化。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信