{"title":"Redesign and Performance Analysis of Medium Flow Coefficient Centrifugal Compressor","authors":"K. Yousef, A. Engeda, A. Hegazy","doi":"10.1115/ajkfluids2019-4903","DOIUrl":null,"url":null,"abstract":"\n In-house design/analysis program is used in this study to redesign and predict the entire performance of an existing centrifugal compressor. The centrifugal compressor experimental data from a cooperative company is validated first with the 3D CFD simulation for a single passage flow. The validation shows an acceptable performance discrepancy between experimental data and CFD for the existing impeller. Then, a redesign procedure by the in-house program is carried out to get more efficient impeller based on the experimental data. This redesigned impeller is re-implemented in the CFD simulation to be compared with in-house program analysis data. The validation shows a good performance comparison between CFD and in-house program for the redesigned impeller. Moreover, this procedure succeeds to improve the redesigned stage efficiency and work coefficient with 6.79%, and 10.55% compared to the experimental impeller, respectively.","PeriodicalId":270000,"journal":{"name":"Volume 3B: Fluid Applications and Systems","volume":"62 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2019-07-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Volume 3B: Fluid Applications and Systems","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1115/ajkfluids2019-4903","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
In-house design/analysis program is used in this study to redesign and predict the entire performance of an existing centrifugal compressor. The centrifugal compressor experimental data from a cooperative company is validated first with the 3D CFD simulation for a single passage flow. The validation shows an acceptable performance discrepancy between experimental data and CFD for the existing impeller. Then, a redesign procedure by the in-house program is carried out to get more efficient impeller based on the experimental data. This redesigned impeller is re-implemented in the CFD simulation to be compared with in-house program analysis data. The validation shows a good performance comparison between CFD and in-house program for the redesigned impeller. Moreover, this procedure succeeds to improve the redesigned stage efficiency and work coefficient with 6.79%, and 10.55% compared to the experimental impeller, respectively.