A wireless 8-channel ECG biopotential acquisition system for dry electrodes

Xiaofei Pu, Lei Wan, Yun Sheng, P. Chiang, Yajie Qin, Zhiliang Hong
{"title":"A wireless 8-channel ECG biopotential acquisition system for dry electrodes","authors":"Xiaofei Pu, Lei Wan, Yun Sheng, P. Chiang, Yajie Qin, Zhiliang Hong","doi":"10.1109/RFIT.2012.6401640","DOIUrl":null,"url":null,"abstract":"A wireless 8-channel biopotential acquisition system for capturing electrocardiogram (ECG) using dry electrodes is presented. The ECG system consists of copper electrodes, a micropowered 8-channel custom ASIC, and an off-the-shelf microprocessor and bluetooth radio. Each analog channel of the custom ECG front-end is composed of a chopper-modulated instrumentation amplifier (CMIA) with chopping spike filter (CSF), a programmable gain amplifier (PGA), and a output buffer. Implemented in standard a 0.35 μm CMOS technology, the ECG front-end consumes 101 μA from a 2.7 V supply, occupying 5 mm2 of chip area. Measurement results show an input impedance of 1 G Ω, an input-referred noise of 0.97 μVrms (0.5 ~ 100 Hz), and a CMRR of 114 dB. Finally, a complete wireless 8-channel ECG monitoring system incorporating this analog front-end is demonstrated, showing successful recordings of a capture ECG waveform using a smart phone.","PeriodicalId":187550,"journal":{"name":"2012 IEEE International Symposium on Radio-Frequency Integration Technology (RFIT)","volume":"62 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2012-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"15","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2012 IEEE International Symposium on Radio-Frequency Integration Technology (RFIT)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/RFIT.2012.6401640","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 15

Abstract

A wireless 8-channel biopotential acquisition system for capturing electrocardiogram (ECG) using dry electrodes is presented. The ECG system consists of copper electrodes, a micropowered 8-channel custom ASIC, and an off-the-shelf microprocessor and bluetooth radio. Each analog channel of the custom ECG front-end is composed of a chopper-modulated instrumentation amplifier (CMIA) with chopping spike filter (CSF), a programmable gain amplifier (PGA), and a output buffer. Implemented in standard a 0.35 μm CMOS technology, the ECG front-end consumes 101 μA from a 2.7 V supply, occupying 5 mm2 of chip area. Measurement results show an input impedance of 1 G Ω, an input-referred noise of 0.97 μVrms (0.5 ~ 100 Hz), and a CMRR of 114 dB. Finally, a complete wireless 8-channel ECG monitoring system incorporating this analog front-end is demonstrated, showing successful recordings of a capture ECG waveform using a smart phone.
一种用于干电极的无线8通道ECG生物电位采集系统
介绍了一种利用干电极捕捉心电图的无线8通道生物电位采集系统。该ECG系统由铜电极、一个微电源8通道定制ASIC、一个现成的微处理器和蓝牙无线电组成。定制ECG前端的每个模拟通道由带斩波尖峰滤波器(CSF)的斩波调制仪表放大器(CMIA)、可编程增益放大器(PGA)和输出缓冲器组成。心电前端采用标准0.35 μm CMOS工艺,2.7 V电源功耗101 μA,芯片面积为5 mm2。测量结果表明,输入阻抗为1 G Ω,输入参考噪声为0.97 μVrms (0.5 ~ 100 Hz), CMRR为114 dB。最后,演示了一个完整的无线8通道心电监测系统,该系统包含该模拟前端,显示了使用智能手机成功记录捕获的心电波形。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信