Study of small signal stability using PSAT including DFIG based wind penetration

R. Pandey
{"title":"Study of small signal stability using PSAT including DFIG based wind penetration","authors":"R. Pandey","doi":"10.3126/jiee.v2i1.36667","DOIUrl":null,"url":null,"abstract":"In early days of power engineering, the power system consisting of synchronous generators faced different low frequency oscillation problems and they were solved by different researchers by using suitably AVR and PSS. Later, the electricity industry is turning increasingly to renewable sources of energy to generate electricity. Wind is the fastest growing and the most widely utilized emerging renewable energy technology for power generation at present. With the increasing penetration of wind power in the power system, the impact in power system performance should be fully investigated, particularly for doubly fed induction generation (DFIG) wind turbine since this type of renewable source is gaining prominence in the power system industry. Main purpose of this study is to examine the impacts of wind power integration in the low grid from low frequency oscillation perspective. The benchmarked Two Area System is considered for this analysis using Power System Analysis Toolbox (PSAT). The critical modes of oscillation are selected from eigenvalue analysis and their participation factors are studied to identify their sensitivity. Also the time domain analysis is run in every cases to study the transient stability. From TAS, concept of local and global mode oscillation can be understood clearly. Replacing synchronous generators in TAS by DFIG WTG one by one of same rating gave conclusion that low frequency stability depends on the location of DFIG penetration and operating scenario. The results show that there is both beneficial and detrimental effects due to DFIG WTGs. The installation of PSS in the critical generators greatly enhances the system damping.","PeriodicalId":263238,"journal":{"name":"Journal of Innovations in Engineering Education","volume":"63 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2019-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Innovations in Engineering Education","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3126/jiee.v2i1.36667","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

In early days of power engineering, the power system consisting of synchronous generators faced different low frequency oscillation problems and they were solved by different researchers by using suitably AVR and PSS. Later, the electricity industry is turning increasingly to renewable sources of energy to generate electricity. Wind is the fastest growing and the most widely utilized emerging renewable energy technology for power generation at present. With the increasing penetration of wind power in the power system, the impact in power system performance should be fully investigated, particularly for doubly fed induction generation (DFIG) wind turbine since this type of renewable source is gaining prominence in the power system industry. Main purpose of this study is to examine the impacts of wind power integration in the low grid from low frequency oscillation perspective. The benchmarked Two Area System is considered for this analysis using Power System Analysis Toolbox (PSAT). The critical modes of oscillation are selected from eigenvalue analysis and their participation factors are studied to identify their sensitivity. Also the time domain analysis is run in every cases to study the transient stability. From TAS, concept of local and global mode oscillation can be understood clearly. Replacing synchronous generators in TAS by DFIG WTG one by one of same rating gave conclusion that low frequency stability depends on the location of DFIG penetration and operating scenario. The results show that there is both beneficial and detrimental effects due to DFIG WTGs. The installation of PSS in the critical generators greatly enhances the system damping.
基于PSAT包括DFIG的小信号稳定性研究
在电力工程的早期,同步发电机组成的电力系统面临着不同的低频振荡问题,不同的研究人员通过适当地使用AVR和PSS来解决这些问题。后来,电力行业越来越多地转向可再生能源发电。风能是目前发展最快、应用最广泛的新兴可再生能源发电技术。随着风电在电力系统中的日益普及,应充分研究其对电力系统性能的影响,特别是对双馈感应发电(DFIG)风力发电机组的影响,因为这种可再生能源在电力系统工业中越来越重要。本研究的主要目的是从低频振荡的角度来考察风电在低电网中并网的影响。使用电力系统分析工具箱(PSAT)对基准双区域系统进行分析。从特征值分析中选择振动的临界模态,研究其参与因子,确定其灵敏度。并在每种情况下进行时域分析,研究暂态稳定性。从TAS可以清楚地理解局部和全局模态振荡的概念。用相同等级的DFIG WTG依次替换TAS中的同步发电机,得出低频稳定性取决于DFIG渗透位置和运行场景的结论。结果表明,DFIG wtg既有有益的影响,也有有害的影响。在关键发电机上安装PSS,大大提高了系统的阻尼。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信